Siemens 5SL3303-7 — 3-Pole MCB (DIN Rail)

Siemens 5SL3303-7 SENTRON MCB, 3-pole C-curve 3 A 4.5 kA

MPN5SL3303-7

Siemens SENTRON 5SL miniature circuit breaker, 5SL3303-7, 3-pole, C-curve, 3 A rated current, 4.5 kA breaking capacity at 400 V AC, 3 module widths.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3303-7 — Identification
ParameterValue
Design / model code5SL3
Brand nameSENTRON
Number of poles3
Suitability for operationResidential buildings/infrastructure
5SL3303-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608984.5 kA
Breaking capacity per IEC 60947-24.5 kA
Overvoltage category3
IP protection classIP20, with connected conductors
Pollution degree2
5SL3303-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Rated frequency50 Hz
5SL3303-7 — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL3303-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

The Siemens 5SL3303-7 is a SENTRON 5SL miniature circuit breaker (MCB) — a 3-pole unit with a C-curve tripping characteristic, rated 3 A at 400 V AC.

In a panel with elevated internal temperature, derate per the manufacturer's curve — the surrounding temperature spec allows periodic +55 °C at 95 % humidity, so the breaker is built for warm enclosures, but the trip threshold shifts. The 4.5 kA SCCR at 400 V AC means it safely interrupts faults up to that level without welding or cascading upstream — coordination with a higher-rated upstream device is required if the prospective fault current exceeds 4.5 kA. The 3-pole design switches all three phases simultaneously, which is critical for three-phase loads where a single-phase trip could backfeed and create a shock hazard. Rated voltage is 400 V AC for multi-phase operation, with a maximum of 440 V AC. The DC rating is 72 V maximum — this is not a DC-rated breaker for solar or battery strings above that voltage. The energy limiting class is 3, meaning it limits let-through energy well, reducing arc-flash risk downstream.

Snap-on DIN rail mount, 3 module widths (54 mm). Sealable with a lockable cover or clip, which matters for LOTO compliance on a circuit that must be positively isolated. Halogen-free and silicon-free construction for environments sensitive to outgassing (clean rooms, medical, data centers).

Frequently asked questions

What is the breaking capacity of 5SL3303-7?

4.5 kA per EN 60898 and IEC 60947-2 at 400 V AC. That is the standard rating for residential and light commercial distribution boards. If your prospective fault current exceeds 4.5 kA, coordinate with an upstream current-limiting device.

Will 5SL3303-7 drop into a panel specified around 5SL3640-7MB without rewiring?

Both are 3-pole SENTRON 5SL MCBs on the same DIN-rail footprint (3 module widths, 54 mm). The 5SL3303-7 is 3 A C-curve; the 5SL3640-7MB is a higher-current variant. No rewiring needed — the bus-bar pitch and terminal layout are identical. Just verify the ampacity and coordination.

Where can I buy 5SL3303-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm price and delivery window.