Siemens 5SL3306-6 — 3-Pole MCB (DIN Rail)

Siemens 5SL3306-6 SENTRON MCB, 3-pole B-curve 6 A 4.5 kA

MPN5SL3306-6

Siemens SENTRON 5SL3306-6 miniature circuit breaker, 3-pole, B-curve, 6 A rated current, 4.5 kA breaking capacity at 400 V AC, 50 Hz, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3306-6 — Identification
ParameterValue
Design / model code5SL3
Brand nameSENTRON
Number of poles3
Suitability for operationResidential buildings/infrastructure
5SL3306-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608984.5 kA
Breaking capacity per IEC 60947-24.5 kA
Overvoltage category3
IP protection classIP20, with connected conductors
5SL3306-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Rated frequency50 Hz
5SL3306-6 — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL3306-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

The Siemens 5SL3306-6 is a SENTRON miniature circuit breaker (MCB) — a 3-pole unit with a B-curve trip characteristic, rated 6 A at 400 V AC, 50 Hz. The B-curve (3–5× In) means it trips fast on moderate overloads — typical for lighting and general-purpose socket circuits where inrush is low. At 3 width units (54 mm wide, 90 mm tall, 76 mm deep), it snaps onto a standard DIN rail in any mounting position, with IP20 protection once the conductors are connected.

The B-curve at 6 A protects wiring and loads that don't see heavy motor-starting surges — think lighting circuits, small appliances, control transformers. The 10 000 mechanical switching cycles are standard for this class; the unit is sealable (tamper-evident) for metering or landlord applications.

At 54 mm wide (3 width units), it occupies three 18 mm module spaces. Overvoltage category III means it's rated for fixed-installation distribution boards, not for downstream equipment. No neutral switching — this is a 3-pole device for 3-phase circuits without a switched neutral.

Frequently asked questions

Where can I buy the 5SL3306-6 and get current pricing?

The 5SL3306-6 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of the 5SL3306-6?

It is a 3-pole B-curve MCB rated 6 A at 400 V AC, 50 Hz, with a breaking capacity of 4.5 kA per EN 60898 and IEC 60947-2. It measures 54 mm wide, 90 mm tall, 76 mm deep, and mounts on a 35 mm DIN rail.

Will the 5SL3306-6 drop into a panel specified around the 5SL4120-7CC?

Both are 3-pole MCBs on a 54 mm footprint, so the mechanical fit is the same. However, the 5SL4120-7CC is a C-curve device at a different current rating — verify the trip characteristic and ampacity match your circuit design before substitution.

MPN