Skip to main content
Siemens 5SL3310-6 — 3-Pole MCB (DIN Rail)

Siemens 5SL3310-6 SENTRON MCB, 10 A, B-Curve, 3-Pole, 4.5 kA

MPN5SL3310-6

Siemens SENTRON 5SL series miniature circuit breaker, order code 5SL3310-6, 3-pole, B-curve, 10 A rated current, 4.5 kA breaking capacity, 400 V AC, 3-module width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3310-6 — Identification
ParameterValue
Design / model code5SL3
Brand nameSENTRON
Number of poles3
Suitability for operationResidential buildings/infrastructure
5SL3310-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 608984.5 kA
Breaking capacity per IEC 60947-24.5 kA
Overvoltage category3
IP protection classIP20, with connected conductors
5SL3310-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Rated frequency50 Hz
5SL3310-6 — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL3310-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturePeriodically +55°C, max. 95% humidity

Product details

Siemens 5SL3310-6 SENTRON MCB — 10 A, B-Curve, 3-Pole

The Siemens 5SL3310-6 is a 3-pole miniature circuit breaker from the SENTRON 5SL series, rated at 10 A with a B tripping characteristic. It snaps onto a DIN rail and occupies 3 width units (54 mm). The B-curve means it trips between 3 and 5 times rated current — standard for residential and light commercial final circuits where inrush is modest (lighting, socket outlets). Breaking capacity is 4.5 kA per both EN 60898 and IEC 60947-2, adequate for most distribution boards in building infrastructure.

Key ratings and what they mean for fit

Rated voltage is 400 V AC, with a maximum of 440 V in multi-phase operation. Breaking capacity is 4.5 kA. Terminals accept solid or stranded conductors from 0.75 to 25 mm², with a tightening torque of 2.5 to 3 N·m. The housing is halogen-free and silicon-free, which matters for panels in environments sensitive to outgassing (clean rooms, certain industrial zones). IP20 protection applies with connected conductors — standard for enclosed distribution boards. Mounting position is any, so the breaker can be installed horizontally or vertically without derating.

Frequently asked questions

What wire sizes does the 5SL3310-6 accept?

Terminals accept solid and stranded conductors from 0.75 to 25 mm². Tightening torque is 2.5 to 3 N·m. The screw terminals are touch-protected.

MPN
5SL3310-6