Skip to main content
Siemens 5SL3316-6 — 3-Pole MCB (DIN Rail)

Siemens 5SL3316-6 SENTRON MCB, 3P B 16A 400V AC, 4.5kA

MPN5SL3316-6

Siemens SENTRON 5SL3316-6, miniature circuit breaker, 3-pole, B characteristic, 16 A, 400 V AC, 4.5 kA breaking capacity per EN 60898, 5 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3316-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL3316-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL3316-6 — Electrical
ParameterValue
Rated current (AC)16 A
Rated voltage (AC, multi-phase)440 V
5SL3316-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL3316-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL3316-6 is a SENTRON miniature circuit breaker — 3-pole, B-curve, rated 16 A at 400 V AC. It breaks 4.5 kA per EN 60898 and 5 kA per IEC 60947-2, covering residential and light commercial infrastructure panels. The B characteristic means it trips between 3 and 5 times rated current, suited for resistive and general-purpose loads where inrush is modest — lighting, socket circuits, control transformers. Three modular width units (54 mm) on the DIN rail, depth 76 mm, installable in any orientation.

Thermal derating and ambient range

Full 16 A rating holds at 30 °C ambient. At 40 °C it derates to 15.23 A, at 45 °C to 14.88 A, and at 55 °C to 13.99 A. The operating ambient range spans -40 °C to 75 °C, with storage exceeding that — the thermal curve governs continuous load, not just survival. Overvoltage category III, pollution degree 2, energy limitation class 3. Mechanical service life 10 000 switching cycles typical.

Panel integration notes

Mounts on standard 35 mm DIN rail, any position. Three modular width units (54 mm total) with 70 mm installation depth behind the panel surface. IP20 with connected conductors — suitable for enclosed distribution boards, not for wet or washdown environments. Sealable, halogen-free, silicon-free construction. Terminal design accommodates the usual 0.2–2.5 mm² solid or stranded copper.

Frequently asked questions

Where can I buy 5SL3316-6 and get a price?

The 5SL3316-6 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability — confirmed at quote time.

What is the breaking capacity of 5SL3316-6?

The 5SL3316-6 breaks 4.5 kA per EN 60898 and 5 kA per IEC 60947-2 at 400 V AC. The higher IEC figure covers industrial panel coordination; the EN figure governs the residential/infrastructure installation standard.

Will 5SL3316-6 drop into a panel specified for 5SL4106-7CC?

Both are 3-pole SENTRON MCBs on a 54 mm DIN-rail footprint, so the mechanical fit is the same. The 5SL3316-6 is a B-curve 16 A unit; the 5SL4106-7CC is a C-curve variant at a different current rating. Check the trip characteristic and ampacity against your circuit design before substituting — the rail and busbar positions match, but the protection curve differs.

MPN
5SL3316-6