Siemens 5SL3316-7 — 3-Pole MCB (DIN Rail)

Siemens SENTRON 5SL3316-7 MCB, 3P C 16A 4.5 kA

MPN5SL3316-7

Siemens SENTRON 5SL3316-7, miniature circuit breaker, 3-pole, C-curve, 16 A, 400 V AC, 4.5 kA (EN 60898), 5 kA (IEC 60947-2), IP20, 54 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3316-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL3316-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 608984.5 kA
Breaking capacity per IEC 60947-25 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL3316-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.8 W
Mechanical service life (operating cycles, typ.)10 000
5SL3316-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL3316-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The 4.5 kA breaking capacity per EN 60898 covers most residential and light commercial panelboard duty; the 5 kA rating per IEC 60947-2 gives a bit more headroom for industrial distribution boards where fault currents run higher.

The 5SL3316-7 occupies 3 modular width units (54 mm total) on a DIN rail, with a 76 mm depth and 90 mm height — standard SENTRON footprint that drops into any 18 mm-pitch enclosure. Mounting position is unrestricted, so it works in vertical or horizontal busbar arrangements.

Accessories and auxiliary devices

The breaker accepts supplementary devices (shunt trip, undervoltage release, auxiliary contacts) — the terminal interface is standard across the SENTRON 5SL series.

Frequently asked questions

What is the breaking capacity of the 5SL3316-7?

The 5SL3316-7 is rated 4.5 kA according to EN 60898 and 5 kA according to IEC 60947-2, both at 400 V AC. The IEC 60947-2 figure is the one to use for industrial distribution board coordination.

Will the 5SL3316-7 fit in a panel originally built for the 5SL4363-7?

Yes, the 5SL3316-7 shares the same 54 mm width (3 MW), 76 mm depth, 90 mm height, and DIN-rail mounting as the 5SL4363-7. It will physically swap without rewiring. The difference is interrupting rating: the 5SL4363-7 is 10 kA per both standards; this unit is 4.5 kA / 5 kA. Verify coordination with the upstream breaker before substituting.

Where can I buy the 5SL3316-7?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN