Siemens 5SL3416-7MB — 4-Pole MCB (DIN Rail)

Siemens 5SL3416-7MB SENTRON MCB, 4P C 16A 4.5kA

MPN5SL3416-7MB
Active

Siemens SENTRON 5SL3 series, 5SL3416-7MB miniature circuit breaker, 4-pole, C tripping characteristic, 16 A rated current, 4.5 kA breaking capacity per EN 60898, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3416-7MB — Identification
ParameterValue
Type / order code5SL3
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL3416-7MB — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)60 V
Voltage typeAC
Rated frequency50 Hz
5SL3416-7MB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608984.5 kA
Rated breaking capacity, per IEC 60947-24.5 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SL3416-7MB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
SealableYes
5SL3416-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL3416-7MB — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)20 000

Product details

What this 4-pole C-curve MCB covers

The Siemens 5SL3416-7MB is a 4-pole miniature circuit breaker (MCB) from the SENTRON 5SL3 family, rated 16 A with a C tripping characteristic. That C-curve means it trips at 5 to 10 times rated current — standard for motor and lighting circuits where inrush is moderate, not for pure resistive loads or high-surge transformers. Breaking capacity is 4.5 kA per both EN 60898 and IEC 60947-2, so it handles fault currents up to that level without welding contacts or failing to clear. Rated voltage is 400 V AC, with a maximum of 440 V in multi-phase operation. The 4-pole design switches all three phases plus neutral (though neutral is not switched internally — it's a 4-pole overcurrent-protected device, not a switched-neutral MCB).

Panel fit and wiring

Mounts on DIN rail in any position — no derating needed for horizontal or vertical orientation. Occupies 4 width units (72 mm wide), 90 mm tall, 76 mm deep, with an installation depth of 70 mm. Terminals accept solid or stranded copper from 0.75 mm² up to 25 mm², tightened to 2.5–3 N·m. That covers most panel wiring from control circuits up to feeder-size conductors. IP20 with conductors connected — fine inside a closed panel, not for wet or dusty environments. Sealable cover is standard, so a lockout/tagout program can secure the toggle.

Lifecycle and sourcing

Current production — no end-of-life notice. The 5SL3416-7MB is a standard catalog item in the SENTRON line, specified in residential and light commercial infrastructure panels.

Frequently asked questions

What wire sizes does 5SL3416-7MB accept?

Solid or stranded copper from 0.75 mm² up to 25 mm². Terminal torque spec is 2.5 to 3 N·m.

MPN
5SL3416-7MB