Skip to main content
Siemens 5SL3420-7MB — 4-Pole MCB (DIN Rail)

Siemens 5SL3420-7MB SENTRON MCB, 4P C-20A, 4.5 kA

MPN5SL3420-7MB
Active

Siemens SENTRON 5SL3420-7MB miniature circuit breaker, 4-pole, C-trip characteristic, 20 A rated current, 4.5 kA breaking capacity per EN 60898, 5 kA per IEC 60947-2, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3420-7MB — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL3420-7MB — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC20 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL3420-7MB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL3420-7MB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL3420-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL3420-7MB — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)20 000

Product details

Siemens 5SL3420-7MB SENTRON MCB — 4-Pole C-20A for Panel Protection

It breaks 4.5 kA per EN 60898 and 5 kA per IEC 60947-2, covering both residential and industrial coordination requirements. Active in production per the manufacturer's lifecycle status.

The 4.5 kA Icn (EN 60898) is the rated short-circuit capacity for domestic distribution boards; the 5 kA Ics (IEC 60947-2) is the service breaking capacity for industrial panels, confirming it can clear a fault and be reclosed without replacement. At 40 °C ambient the breaker derates to 19 A, and at 45 °C to 18.6 A — factor that into the load schedule if the panel runs warm. Four modular-width units (72 mm) snap onto standard DIN rail. The IP20 rating applies with connected conductors, so the busbar stabs and terminals are finger-safe once wired. Sealable, halogen-free, and silicon-free construction suits clean-room or food-processing environments where outgassing matters.

Integration Notes

The 4-pole design (3 phases + neutral) fits three-phase distribution boards. Mechanical endurance is 20 000 switching cycles.

Frequently asked questions

Where can I buy 5SL3420-7MB and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

What is the breaking capacity of 5SL3420-7MB?

It is rated 4.5 kA per EN 60898 and 5 kA per IEC 60947-2. The higher IEC figure means it meets industrial service-break requirements, not just domestic coordination.

What compliance documentation does the brand provide for 5SL3420-7MB?

As a Siemens SENTRON product, it carries CE marking and is designed to EN 60898 and IEC 60947-2. The halogen-free and silicon-free construction supports RoHS and REACH compliance. Specific declarations are available on request.

MPN
5SL3420-7MB