Siemens 5SL3505-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL3505-7 SENTRON MCB, 0.5 A, C-curve, 1P+N, 4.5 kA

MPN5SL3505-7

Siemens SENTRON 5SL miniature circuit breaker, order code 5SL3505-7, 0.5 A rated current, C tripping characteristic, 1P+N, 4.5 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL3505-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL3505-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)4.5 kA
Overvoltage category3
5SL3505-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL3505-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL3505-7 SENTRON MCB, 0.5 A, C-curve

The Siemens 5SL3505-7 is a 1P+N miniature circuit breaker from the SENTRON 5SL series, rated at 0.5 A with a C tripping characteristic.

At 0.5 A, this MCB protects a very low-current circuit — think control transformers, small signal supplies, or a single lighting branch with a handful of LED fixtures. That is common in single-phase final circuits where you want to isolate both poles for safe maintenance. Rated voltage is 230 V AC (single-phase operation up to 250 V AC), so it drops straight into a standard 230 V residential or light commercial distribution board.

Panel integration and installation

The 5SL3505-7 occupies 2 width units (36 mm) on a DIN rail, with an installation depth of 70 mm and overall depth of 76 mm. Terminal capacity accepts solid or stranded conductors from 0.75 mm² up to 25 mm², and the tightening torque range is 2.5–3 N·m. It is sealable, halogen-free, and silicon-free — relevant for installations where outgassing or contamination must be controlled (e.g., medical or clean-room environments). IP20 with connected conductors; mounting position any, so it fits in horizontal or vertical panel layouts.

Frequently asked questions

What is the breaking capacity of the 5SL3505-7?

The breaking capacity is 4.5 kA per both EN 60898 and IEC 60947-2, suitable for standard residential and light commercial fault levels.

Where can I buy the 5SL3505-7?

This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SL3505-7