Siemens 5SL3506-6 — 1-Pole MCB (DIN Rail)

Siemens 5SL3506-6 SENTRON MCB, 1+N Pole, B-Curve, 6 A, 4.5 k

MPN5SL3506-6

Siemens SENTRON 5SL3506-6, miniature circuit breaker, 1+N-pole, B-curve, 6 A, 4.5 kA breaking capacity per EN 60898, 230 V AC, 2 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3506-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL3506-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)4.5 kA
Energy limitation class3
Overvoltage categoryIII
5SL3506-6 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL3506-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL3506-6 is a 1+N-pole miniature circuit breaker from the SENTRON 5SL series, rated 6 A with a B-curve trip characteristic. It breaks faults up to 4.5 kA per EN 60898 and IEC 60947-2, which covers the majority of residential and light-commercial distribution boards. The 1+N configuration switches the line and switches the neutral, so it's suited for single-phase final circuits where neutral isolation is required.

The 6 A B-curve trips between 3 and 5 times rated current — typical for lighting and socket-outlet circuits where inrush is low. The 2-module-width (36 mm) body snaps onto standard DIN rail, and the IP20 rating with connected conductors means it's protected against finger contact once wired — fine for enclosed distribution boards, not for wet environments.

Frequently asked questions

What is the breaking capacity of 5SL3506-6?

4.5 kA per both EN 60898 and IEC 60947-2, at 230 V AC.

Where can I buy 5SL3506-6?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SL3506-6 drop into a panel specified around 5SL6516-6YA without rewiring?

Both are 1+N-pole SENTRON MCBs on a 2-MW DIN-rail footprint, so the mechanical fit is the same. The difference is the rating — 5SL3506-6 is 6 A B-curve; 5SL6516-6YA is a different rating and curve. Verify the load requirements before swapping.

MPN
5SL3506-6