Skip to main content
Siemens 5SL3606-7 — Miniature Circuit Breakers (MCB)

Siemens 5SL3606-7 SENTRON MCB, 6A C-Curve 3P+N 4.5kA

MPN5SL3606-7

Siemens SENTRON 5SL3606-7 miniature circuit breaker, 400 V AC, 6 A, C-curve, 3P+N, 4.5 kA (EN 60898), 4 modules wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL3606-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SL3606-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

Siemens SENTRON 5SL3606-7 — 6 A C-Curve MCB, 3P+N, 4.5 kA

The Siemens SENTRON 5SL3606-7 is a 4-pole miniature circuit breaker (3P+N) rated at 6 A with a C-trip characteristic, designed for 400 V AC residential and infrastructure branch circuits. Its 4.5 kA interrupting capacity per EN 60898 and 5 kA per IEC 60947-2 cover standard lighting, socket-outlet, and light commercial loads where fault levels stay under that threshold.

The C-curve (trips at 5–10× rated current) suits circuits with moderate inrush — think small motors, transformers, or groups of LED drivers — where a B-curve would nuisance-trip but a D-curve would delay too long for cable protection. The 6 A rating protects 1.5 mm² copper conductors in standard PVC installation methods. At 400 V AC, the 4.5 kA (EN 60898) / 5 kA (IEC 60947-2) SCCR means the breaker clears faults up to that level without welding contacts or cascading failure upstream — verify your prospective short-circuit current at the panelboard before specifying. The 3P+N design switches all three phases and switches the neutral, which is required in some regional wiring rules (e.g., UK, Australia) for final subcircuits where the neutral is not solidly bonded.

Any mounting position is permitted. Sealable with a lockable cover to prevent unauthorized operation. Halogen-free and silicon-free construction reduces corrosive gas risk in confined enclosures.

Frequently asked questions

How do I get current pricing and availability for 5SL3606-7?

Submit an RFQ. This part is sourced and quoted to order through independent distribution; current pricing and stock levels are confirmed at quote time.

What is the difference between 5SL3606-7 and 5SL4363-7?

The 5SL4363-7 is a 3-pole (3P) version with a higher interrupting capacity (10 kA per both EN 60898 and IEC 60947-2) and a wider power loss per pole (5 W). The 5SL3606-7 is 3P+N, 4.5/5 kA, with lower per-pole losses (1.6 W). They share the same 76 mm depth and 90 mm height, but the 5SL4363-7 is 54 mm wide (3 modules) versus 72 mm (4 modules) for the 5SL3606-7. They are not drop-in interchangeable without rewiring the neutral.

Will 5SL3606-7 drop into a panel specified around 5SL4363-7 without rewiring?

No. The 5SL3606-7 is 4-pole (3P+N) and occupies 72 mm (4 modules) versus the 5SL4363-7's 3-pole (3P) 54 mm (3 modules). The neutral conductor must be routed through the switched neutral pole on the 5SL3606-7, which the 5SL4363-7 does not have. Panel space and wiring both differ.

What compliance documentation does Siemens provide for 5SL3606-7?

Siemens provides a declaration of conformity for the SENTRON 5SL series covering the Low Voltage Directive (2014/35/EU) and relevant harmonized standards (EN 60898-1, EN 60947-2). The breaker carries CE marking. RoHS and REACH compliance is standard for current-production SENTRON products.