Siemens 5SL3620-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL3620-7 SENTRON MCB, 4P C-20A 4.5kA

MPN5SL3620-7

Siemens SENTRON 5SL miniature circuit breaker, 5SL3620-7, 4-pole (3P+N), C-curve, 20 A rated, 4.5 kA breaking capacity, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3620-7 — Identification
ParameterValue
Type / order code5SL3
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL3620-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC20 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50 Hz
5SL3620-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608984.5 kA
Rated breaking capacity, per IEC 60947-24.5 kA
Overvoltage category3
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL3620-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL3620-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SL3620-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SL3620-7 is a SENTRON 5SL miniature circuit breaker (MCB) in a 4-pole (3P+N) configuration, rated 20 A with a C tripping curve and 4.5 kA breaking capacity per EN 60898 and IEC 60947-2. It's designed for residential and infrastructure final-distribution panels where you need neutral conductor switching and a 400 V AC supply. At 20 A, it handles a typical 4.5 kW resistive load on 230 V single-phase or a 13.8 kW three-phase load at 400 V.

Key ratings with the so-what

Breaking capacity of 4.5 kA at 400 V AC per both EN 60898 and IEC 60947-2 — this is the standard domestic/infrastructure level. If your service entrance has a prospective short-circuit current above 4.5 kA, you need a higher-rated breaker upstream or a current-limiting device. The energy limiting class of 3 means it restricts let-through energy during a fault, which helps with downstream component protection. Rated voltage is 400 V AC for single-phase, with a maximum of 440 V AC in multi-phase operation. The DC maximum rating is 72 V — if you're switching DC loads, keep it below that. Not a cycling device for motor starting; use a contactor for that.

Width is 72 mm (4 width units of 18 mm each), depth 76 mm, height 90 mm. Installation depth is 70 mm. The sealable feature (yes) lets you lock the toggle in position to prevent unauthorized switching — useful for safety-critical circuits or rental-metered sub-distribution.

For a BOM line or a line-down replacement, the fit is confirmed: 4-pole C-curve 20 A at 4.5 kA.