Siemens 5SL3640-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL3640-6 SENTRON MCB, 40A B Curve 3P+N, 4.5kA

MPN5SL3640-6

Siemens SENTRON 5SL miniature circuit breaker, 5SL3640-6, 40 A, B characteristic, 3P+N, 400 V AC, 4.5 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL3640-6 — Identification
ParameterValue
Type / order code5SL3
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL3640-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC40 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50 Hz
5SL3640-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608984.5 kA
Rated breaking capacity, per IEC 60947-24.5 kA
Overvoltage category3
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL3640-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL3640-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SL3640-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SL3640-6 is a SENTRON miniature circuit breaker rated 40 A at 400 V AC with a B tripping characteristic, switching 3 poles plus switched neutral (3P+N).

This breaker occupies 4 width units (72 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm — no surprise for a 4-pole MCB; it fits standard distribution boards without a deep enclosure. The operating range spans -40 to 75 °C, with periodic exposure to +55 °C and 95% humidity allowed, which covers unheated utility rooms and outdoor-rated enclosures.

The B characteristic (3-5x In) means it holds through normal resistive load starts but trips fast on a dead short; don't use it on circuits with high inrush like large transformers or multiple motor starters without checking the trip curve. The neutral pole is switched (3P+N), so it disconnects the neutral as well as the phases — required in some regional wiring codes and useful for full isolation during maintenance.

Frequently asked questions

Where can I buy the 5SL3640-6 and how do I get a price?

The 5SL3640-6 is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the key ratings of the 5SL3640-6?

40 A rated current, 400 V AC, B tripping characteristic, 3P+N poles, 4.5 kA breaking capacity per EN 60898 and IEC 60947-2. It occupies 4 width units (72 mm) on DIN rail and operates from -40 to 75 °C.

Will the 5SL3640-6 drop into a panel specified for the 5SL6606-7YA without rewiring?

Not directly — the 5SL6606-7YA is a different SENTRON series with different ratings and possibly a different physical footprint. The 5SL3640-6 is a 40 A B curve 3P+N breaker at 4.5 kA; verify your panel's SCCR, current rating, and tripping characteristic before substituting. The DIN-rail mounting is standard, but terminal positions and busbar compatibility may differ.