5SL4102-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL4102-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL4102-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4102-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL4102-7CC is a 1-pole miniature circuit breaker with C-curve tripping characteristic, rated 2 A and a breaking capacity of 10 kA according to EN 60898 at 400 V AC.

At 2 A, this is a low-current branch protection, not a main feeder or motor circuit. Single-pole construction means it switches only the phase conductor; neutral is not switched. Rated for 250 V single-phase or 400 V three-phase (multi-phase operation at 440 V max). The 72 V DC maximum rating covers some DC control circuits, but this is primarily an AC-rated device. The 18 mm width (1 modular unit) and 76 mm depth fit standard Siemens SENTRON enclosures and most DIN-rail panels.

Deployment context

Sealable design allows lockout/tagout for maintenance isolation. Halogen-free and silicon-free construction suits environments with sensitive electronics or cleanroom requirements.

Frequently asked questions

What is the breaking capacity of 5SL4102-7CC?

The 5SL4102-7CC has a breaking capacity of 10 kA according to EN 60898 at 400 V AC, suitable for standard residential and infrastructure distribution panels.

What is the difference between 5SL4102-7CC and the 3-pole 5SL4363-7?

The 5SL4363-7 is a 3-pole version (54 mm wide, 3 modular units) with the same C-curve and 10 kA breaking capacity, but rated for higher current. The 5SL4102-7CC is a 1-pole 2 A unit at 18 mm wide — they are not drop-in interchangeable; a panel designed for the 3-pole unit would need rewiring to accept a single-pole breaker.