Skip to main content
Siemens 5SL4104-7RC — 1-Pole MCB (DIN Rail)

Siemens 5SL4104-7RC SENTRON MCB, 1P C 4A 10kA

MPN5SL4104-7RC
Active

Siemens SENTRON 5SL4104-7RC, miniature circuit breaker, 1-pole, C-curve, 4 A, 10 kA breaking capacity per EN 60898, 240/415 V AC, 1 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4104-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL4104-7RC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL4104-7RC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4104-7RC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4104-7RC is a SENTRON miniature circuit breaker — one pole, C-curve trip characteristic, rated 4 A with a 10 kA breaking capacity per EN 60898 at 415 V AC. The 1-pole design means it switches only the phase — neutral is not broken inside the device, so the panel builder must provide a separate neutral bar. Installation depth is 70 mm into the enclosure; overall depth 76 mm. The 18 mm width (one modular unit) packs tightly on a DIN rail — useful when backpan density is a constraint.

Deployment context — where this lives in a panel

Sealable (padlockable toggle) allows lockout/tagout on the circuit without removing the breaker. The -40 °C to 75 °C operating range covers unheated service entrances and enclosures near process heat; the 75 °C upper limit is the breaker's internal temperature rise plus ambient, not a surface-touch rating.

Frequently asked questions

What is the 5SL4104-7RC used for?

It is a 1-pole C-curve miniature circuit breaker rated 4 A with a 10 kA breaking capacity per EN 60898, used for final-circuit overcurrent and short-circuit protection in residential and infrastructure distribution boards at 240/415 V AC.

Will the 5SL4104-7RC drop into a panel specified around the 5SL4363-7?

The 5SL4363-7 is a 3-pole version (54 mm wide, three modular units) with otherwise identical depth and height; the 5SL4104-7RC is 1-pole at 18 mm wide. It fits the same DIN rail and enclosure cutout, but you cannot populate a 3-pole slot with a single 1-pole unit without a blanking piece or a different busbar arrangement.

Where can I buy the 5SL4104-7RC?

Sourced and quoted to order through independent industrial-automation distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
5SL4104-7RC