Skip to main content
Siemens 5SL4105-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL4105-7 SENTRON MCB, 1P, 0.5 A, C-Curve, 10 kA

MPN5SL4105-7
Active

Siemens SENTRON 5SL4105-7, 1-pole miniature circuit breaker, 0.5 A rated current, C tripping characteristic, 10 kA breaking capacity per EN 60898, 1 MW unit width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4105-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL4105-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)10 kA
Energy limitation class3
Overvoltage categoryIII
5SL4105-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4105-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL4105-7 SENTRON MCB — 0.5 A, C-Curve, 1-Pole

The Siemens 5SL4105-7 is a 1-pole miniature circuit breaker from the SENTRON series, rated at 0.5 A at 400 V AC with a C tripping characteristic. The C-curve means it is designed for moderate inrush currents — typical for lighting circuits, small transformers, and control transformers where the start-up surge is higher than a resistive load but not as high as a motor.

The 0.5 A rating is valid at 30 °C ambient. At 40 °C the continuous current derates to 0.47 A; at 45 °C to 0.46 A; at 55 °C to 0.43 A.

Mounting and Installation Notes

The installation depth behind the panel is 70 mm; the overall depth is 76 mm. Degree of pollution 2 and overvoltage category III are the standard ratings for a fixed-installation distribution board.

Frequently asked questions

What is the breaking capacity of 5SL4105-7?

The breaking capacity is 10 kA per EN 60898 and also 10 kA per IEC 60947-2, which covers the standard fault-interruption requirement for most final sub-circuits in a building installation.

What is the width of 5SL4105-7 in modular units?

The 5SL4105-7 occupies 1 modular width unit, which is 18 mm on a standard DIN rail.

Where can I buy 5SL4105-7 and how is it quoted?

The 5SL4105-7 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL4105-7