Skip to main content
Siemens 5SL4108-8 — 1-Pole MCB (DIN Rail)

Siemens 5SL4108-8 SENTRON MCB, 1P D 8A 10kA

MPN5SL4108-8
Active

Siemens SENTRON 5SL4 series, miniature circuit breaker, 1-pole, D tripping characteristic, 8 A rated current, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 400 V AC, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4108-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SL4108-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage category3
5SL4108-8 — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4108-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4108-8 is a 1-pole SENTRON miniature circuit breaker with a D tripping characteristic, rated 8 A at 400 V AC. The 10 kA breaking capacity (per EN 60898 and IEC 60947-2) tells you it can safely interrupt a fault current up to that level without welding contacts or cascading upstream; that's the standard for residential and light commercial distribution boards in most European and Asian installations. The single-pole format (1P) switches the line conductor only, so it's used in single-phase branch circuits or as a phase-level protector in multi-pole assemblies.

Deployment context

The manufacturer lists suitability for residential buildings and infrastructure, which aligns with the 10 kA SCCR and 400/230 V network voltages common in those environments.

Halogen-free and silicon-free construction, rated for ambient temperatures from -40 °C to +75 °C with up to 95% humidity at +55 °C. Sealable design allows lockout/tagout for maintenance isolation.

Frequently asked questions

Where can I buy 5SL4108-8 and how is it quoted?

The 5SL4108-8 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 5SL4108-8?

The 5SL4108-8 has a 10 kA breaking capacity per both EN 60898 and IEC 60947-2, which is the standard rating for residential and light commercial distribution boards.

What does the D-curve mean on this MCB?

The D tripping characteristic allows magnetic trips at 10–20× the 8 A rated current, making it suitable for motor, transformer, or lighting ballast circuits where startup inrush would nuisance-trip a B or C curve breaker.

Will 5SL4108-8 fit a standard DIN-rail panel?

Yes, at 18 mm width (1 modular unit) and 76 mm depth, it snaps onto standard DIN rail in any mounting position and fits flush in distribution boards with 70 mm installation depth.

MPN
5SL4108-8