Siemens 5SL4108-8CC — 1-Pole MCB (DIN Rail)

Siemens 5SL4108-8CC SENTRON MCB, 1P D 8A 10kA

MPN5SL4108-8CC
Active

Siemens SENTRON 5SL4108-8CC miniature circuit breaker, 1-pole, D tripping characteristic, 8 A rated current, 10 kA breaking capacity per EN 60898, 230/400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4108-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityResidential buildings/infrastructure
5SL4108-8CC — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SL4108-8CC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4108-8CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL4108-8CC SENTRON MCB — 1-pole D-curve 8 A

The Siemens 5SL4108-8CC is a 1-pole miniature circuit breaker from the SENTRON series, with a D tripping characteristic rated at 8 A. It breaks fault currents up to 10 kA per EN 60898 at 230/400 V AC — the standard residential and light commercial interrupting rating. The D-curve means it tolerates the high inrush of motor and transformer loads without nuisance tripping, making it a fit for pump, compressor, or small-drive branch circuits where a C-curve would trip on startup.

What the ratings mean for your panel

Rated 8 A continuous, with a D-curve magnetic trip that holds through the 5–10× In surge typical of motor starts. The 10 kA breaking capacity per EN 60898 certifies it can safely interrupt a 10 kA prospective short-circuit current at 230/400 V — that is the standard for most residential and light commercial distribution boards. Single-pole design (1P) means it switches only the phase; the neutral is not broken. Rated for single-phase operation at 250 V AC and multi-phase at 440 V AC, so it covers both 230 V branch circuits and 400 V three-phase panels when used on one phase. The 18 mm width (1 modular unit) snaps onto standard DIN rail and occupies one slot in a distribution board. Depth of 76 mm and height of 90 mm keep it flush with adjacent devices. Mounting position is unrestricted — any orientation works. The IP20 rating (with connected conductors) is typical for enclosed panel use; no washdown or outdoor exposure without an outer enclosure. Rated for ambient temperatures from -40 °C to 75 °C, covering unheated enclosures in cold climates and warm cabinets near transformers. The 0.8 W power loss per pole at rated current is low enough to ignore for thermal budgeting in a populated board. Supplementary devices (auxiliary contacts, shunt trips, alarm switches) can be snapped onto the right side — the product extension feature is supported.

Frequently asked questions

Where can I buy 5SL4108-8CC and how do I get a price?

The 5SL4108-8CC is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing.

What is the difference between 5SL4108-8CC and 5SL4363-7?

The 5SL4363-7 is a 3-pole C-curve 63 A MCB in a 54 mm (3-module) width, while the 5SL4108-8CC is a 1-pole D-curve 8 A in 18 mm width. They share the same SENTRON family, 10 kA breaking capacity, and 76 mm depth, but differ in poles, curve, current rating, and footprint — they are not drop-in replacements for each other.

What compliance documentation does Siemens provide for 5SL4108-8CC?

The 5SL4108-8CC carries a 10 kA breaking capacity rating per EN 60898, is halogen-free and silicon-free, and is rated for overvoltage category III with pollution degree 2. Standard Siemens declarations for RoHS and REACH are available on request.