Skip to main content
Siemens 5SL4132-7CC — 1-Pole MCB (DIN Rail)

5SL4132-7CC SENTRON MCB, 1P C 32A 10kA

MPN5SL4132-7CC
Active

Siemens SENTRON 5SL miniature circuit breaker, 5SL4132-7CC, 1-pole, C tripping characteristic, 32 A rated current, 10 kA breaking capacity per EN 60898, 18 mm width, 76 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4132-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SL4132-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)10 kA
Overvoltage category3
5SL4132-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.0.75 mm²
Torque, max.25 mm²
SealableYes
5SL4132-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL4132-7CC is a 1-pole miniature circuit breaker (MCB) with a C tripping characteristic, rated 32 A at 230/400 V AC.

The C-curve (5–10× In) means it tolerates moderate inrush — think lighting banks, small motors, or capacitor loads — without nuisance tripping. At 32 A it feeds a 7 kW resistive load or a 4 kW motor circuit comfortably. Width is 18 mm (one modular unit), depth 76 mm — fits any standard 35 mm DIN-rail enclosure.

Where it is used

Designed for residential buildings and infrastructure — final subcircuits in distribution boards, lighting, socket outlets, and small appliance feeds.

Frequently asked questions

Where can I buy 5SL4132-7CC and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

Will 5SL4132-7CC drop into a panel that was specified around 5SL3120-6MB without rewiring?

Both are 1-pole SENTRON 5SL MCBs on the same 18 mm footprint, so the mechanical fit is identical. The key difference is the tripping characteristic and rating: 5SL3120-6MB carries a B-curve at a lower current, while this C-curve 32 A unit handles higher inrush and load. No rewiring needed for the swap, but verify the branch circuit's fault-current rating and load profile.

What is 5SL4132-7CC's listed depth (76 mm) on this component line?

The depth is 76 mm, with an installation depth of 70 mm — that's the dimension behind the DIN rail.

What is 5SL4132-7CC's listed width (18 mm) on this component line?

Width is 18 mm, which is one modular unit (1 MW) — standard for single-pole MCBs.

MPN