Siemens 5SL4140-8 — 1-Pole MCB (DIN Rail)

Siemens 5SL4140-8 SENTRON MCB, 1P D 40 A, 10 kA, 400 V AC

MPN5SL4140-8
Active

Siemens SENTRON 5SL4 series, 5SL4140-8 miniature circuit breaker, 1-pole, D tripping characteristic, 40 A rated current, 10 kA breaking capacity, 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4140-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityResidential buildings/infrastructure
5SL4140-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage category3
5SL4140-8 — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL4140-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4140-8 is a SENTRON 5SL4-series miniature circuit breaker (MCB) designed for overcurrent and short-circuit protection in residential and infrastructure installations.

What the D-curve and ratings mean for fit

For a 1-pole breaker on a 400 V AC line, the single pole switches the phase; the neutral is not switched (neutral conductor switching: No). The maximum operating voltage for multi-phase operation is 440 V AC, so the breaker can be used on 400/440 V systems without derating the voltage side.

The screw terminals accept solid or stranded conductors from 0.75 to 25 mm²; the tightening torque range is 2.5 to 3 N·m.

Storage temperature extends from -40 to +75 °C. The overvoltage category is 3, and the energy limiting class is 3. The product is classified per DIN EN 61346-2 and DIN EN 81346-2 as function F (protection).

Frequently asked questions

What is the breaking capacity of the 5SL4140-8?

The breaking capacity is 10 kA per both EN 60898 and IEC 60947-2. This means the breaker can safely interrupt fault currents up to 10,000 A without damage or upstream cascading.

What conductor sizes does the 5SL4140-8 accept?

The screw terminals accept solid or stranded conductors from 0.75 mm² up to 25 mm². The recommended tightening torque is 2.5 to 3 N·m.

Where can I buy the 5SL4140-8 and how is it quoted?

The 5SL4140-8 is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL4140-8 drop into a panel designed for the 5SL3120-6MB?

Both are 1-pole SENTRON 5SL-series MCBs with the same 18 mm width and DIN-rail footprint, so the 5SL4140-8 will physically fit the same rail position. However, the 5SL4140-8 is a 40 A D-curve, while the 5SL3120-6MB is a different rating and characteristic; verify the circuit's required current and trip curve before substitution.