Skip to main content
Siemens 5SL4201-7CC — 2-Pole MCB (DIN Rail)

Siemens 5SL4201-7CC SENTRON MCB, 2-pole C-curve 1 A 10 kA

MPN5SL4201-7CC
Active

Siemens SENTRON 5SL4201-7CC, 2-pole miniature circuit breaker, C-curve, 1 A rated, 10 kA breaking capacity at 400 V AC, 2 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4201-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4201-7CC — Electrical
ParameterValue
Number of poles2
5SL4201-7CC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL4201-7CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4201-7CC — Environmental
ParameterValue
Pollution degree2
5SL4201-7CC — Specifications
ParameterValue
Energy Limitation Class3

Product details

Siemens 5SL4201-7CC SENTRON MCB – 2-pole, C-curve, 1 A

The Siemens 5SL4201-7CC is a 2-pole miniature circuit breaker from the SENTRON family, rated 1 A with a C tripping characteristic and a 10 kA breaking capacity at 400 V AC per EN 60898. That 10 kA SCCR means it can safely clear a fault up to 10,000 A without welding its contacts or cascading the fault upstream — important for selectivity in a residential or light commercial distribution board where the upstream main breaker is typically rated higher.

This MCB occupies 2 modular width units (36 mm) on a standard DIN rail, with a depth of 76 mm and a 70 mm installation depth — it sits flush with the rail and leaves room for wiring behind the panel door. Vibration resistance to 50 m/s² at 25–150 Hz per IEC 60068-2-6 means it holds up on a machine panel or in a mobile installation.

At 30 °C ambient, the MCB carries its full 1 A rating. At 40 °C it derates to 0.95 A, at 45 °C to 0.92 A, and at 50 °C to 0.89 A. By 55 °C you're down to 0.86 A.

Frequently asked questions

What is the breaking capacity of the 5SL4201-7CC?

It is rated 10 kA at 400 V AC per EN 60898, which is the standard breaking capacity for residential and light commercial distribution boards.

Where can I buy the 5SL4201-7CC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL4201-7CC drop into a panel specified for 5SL4106-7CC?

Both are 2-pole SENTRON MCBs with the same 36 mm width and DIN-rail mounting, so physically they swap. The difference is rating: 5SL4106-7CC is a B-curve 6 A, while this one is C-curve 1 A — verify the circuit's load and coordination requirements before substituting.

MPN