Skip to main content
Siemens 5SL4202-7RC — 2-Pole MCB (DIN Rail)

Siemens 5SL4202-7RC SENTRON MCB, 2-Pole C-Curve 2A 10kA

MPN5SL4202-7RC
Active

Siemens SENTRON miniature circuit breaker, 5SL4202-7RC, 2-pole, C-curve, 2 A rated, 10 kA breaking capacity per EN 60898 at 415 V AC, 1 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4202-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4202-7RC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value415 V
5SL4202-7RC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL4202-7RC — Mechanical
ParameterValue
Modular width units1
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4202-7RC — Environmental
ParameterValue
Pollution degree2
5SL4202-7RC — Specifications
ParameterValue
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value250 V
Energy Limitation Class3

Product details

Siemens SENTRON 5SL4202-7RC — 2-pole C-curve MCB at 2 A

The Siemens SENTRON 5SL4202-7RC is a 2-pole miniature circuit breaker rated 2 A with a C tripping characteristic and a 10 kA breaking capacity per EN 60898 at 415 V AC. It occupies a single modular width unit (18 mm) on DIN rail, making it a compact choice for residential and infrastructure branch circuits where the load is modest but the fault current potential is industrial-grade. At 2 A it is typically used for control transformers, lighting contactor coils, or PLC power supplies — not main feeders.

At 18 mm wide (1 MW), 76 mm deep, and 90 mm tall, the 5SL4202-7RC snaps onto standard 35 mm DIN rail and needs 70 mm of enclosure depth behind the panel. Mounting position is unrestricted, and the IP20 rating (with conductors connected) is typical for enclosed distribution boards.

Rated 415 V AC (multi-phase) with a maximum of 440 V AC, and 250 V AC single-phase. DC rated to 72 V maximum — usable for DC control circuits within that limit.

Frequently asked questions

Where can I buy 5SL4202-7RC?

The 5SL4202-7RC is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SL4202-7RC and 5SL4363-7?

The 5SL4363-7 is a 3-pole version (63 A, C-curve) in a 54 mm wide housing. It will not drop into a 2-pole, 18 mm DIN slot without reworking the panel layout and resizing the branch circuit protection. The 5SL4202-7RC is the correct 2 A, 2-pole variant for a 1 MW position.

What compliance documentation is available for 5SL4202-7RC?

As a SENTRON series MCB, the 5SL4202-7RC carries CE marking per the Low Voltage Directive and is designed to meet EN 60898 and IEC 60947-2. RoHS and REACH compliance is standard for Siemens industrial control products. Specific declarations are available from Siemens upon request.