Skip to main content
Siemens 5SL4202-8 — 2-Pole MCB (DIN Rail)

Siemens 5SL4202-8 SENTRON MCB, 2P D-curve 2A 10kA

MPN5SL4202-8
Active

Siemens SENTRON 5SL4202-8 miniature circuit breaker, 2-pole, D-curve, 2 A, 10 kA breaking capacity per EN 60898 / IEC 60947-2 at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4202-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4202-8 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL4202-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SL4202-8 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4202-8 — Environmental
ParameterValue
Pollution degree2
5SL4202-8 — Specifications
ParameterValue
According to EN 60898 rated value10 kA
Energy Limitation Class3

Product details

Siemens 5SL4202-8 SENTRON MCB — 2-pole D-curve 2 A for inductive and motor-start loads

The D-curve means it tolerates the inrush current of motor loads, transformers, or inductive equipment without nuisance tripping — the magnetic trip fires between 10× and 20× rated current, so a 2 A breaker holds through the start-up spike of a fractional-horsepower motor or a small solenoid bank.

Breaking capacity and voltage ratings — selectivity and SCCR headroom

Maximum operating voltage is 440 V AC in multi-phase operation, covering 400 V three-phase systems with headroom for nominal line variations. Compared to the C-curve 5SL6220-7 (same 2-pole, 2 MW, but 6 kA breaking capacity), the 5SL4202-8 offers the higher 10 kA rating and the D-curve — the choice hinges on whether your downstream load is resistive (C) or inductive/motor (D), and whether your available fault current exceeds 6 kA.

Integration and mounting — DIN-rail fit, sealable, supplementary devices

Sealable design (padlockable toggle) for lockout/tagout compliance; halogen-free and silicon-free construction for environments sensitive to outgassing (clean rooms, food processing).

Frequently asked questions

Will the 5SL4202-8 fit in a panel designed for the 5SL4363-7?

No — the 5SL4363-7 is a 3-pole, 3 MW (54 mm wide) C-curve breaker, while the 5SL4202-8 is 2-pole, 2 MW (36 mm wide) D-curve. The footprint and pole count differ; it will not drop into the same DIN-rail position without rewiring and a blanking plate.

MPN
5SL4202-8