Siemens 5SL4204-7 — 2-Pole MCB (DIN Rail)

Siemens 5SL4204-7 SENTRON MCB, 2P C 4A 10kA

MPN5SL4204-7
Active

Siemens SENTRON 5SL4204-7, 2-pole miniature circuit breaker, C-curve, 4 A, 400 V AC, 10 kA breaking capacity, 2 MW.

$16.51Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4204-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4204-7 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL4204-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL4204-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4204-7 — Environmental
ParameterValue
Pollution degree2
5SL4204-7 — Specifications
ParameterValue
According to EN 60898 rated value10 kA
Energy Limitation Class3

Product details

The Siemens SENTRON 5SL4204-7 is a 2-pole miniature circuit breaker rated 4 A with a C tripping characteristic, designed for 400 V AC systems at 50/60 Hz. Its 10 kA breaking capacity is certified to both EN 60898 and IEC 60947-2, meaning it clears fault currents up to 10 kA without welding its contacts or cascading failure upstream — that's the figure that governs coordination with the upstream protective device in a distribution board.

Occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm. Snap-on mounting in any position — no derating for upside-down or sideways installs.

C-curve trips at 5–10× rated current (20–40 A magnetic trip), so it's sized for moderate inrush loads like small motor starters, lighting banks, and transformer primaries — not for purely resistive loads (B-curve) or high-inrush drives (D-curve). The 4 A rating at 400 V AC gives 2.7 kVA per pole at unity power factor. Power loss per pole is 1.2 W in hot operating state; two poles dissipate 2.4 W total — negligible in a ventilated enclosure but worth noting if the breaker is sealed in a non-ventilated sub-panel.

Compliance and environment

Halogen-free and silicon-free construction. Sealable for lockout/tagout.

Frequently asked questions

What is the breaking capacity of 5SL4204-7?

10 kA per both EN 60898 and IEC 60947-2. That's the same rating for domestic and industrial certification paths.

Where can I buy 5SL4204-7 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
5SL4204-7