Siemens 5SL4213-8 SENTRON MCB, 2P D 13 A, 10 kA

MPN5SL4213-8
Active

Siemens SENTRON 5SL4 series, miniature circuit breaker (MCB), 2-pole, D tripping characteristic, 13 A rated current, 10 kA breaking capacity, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4213-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4213-8 — Electrical
ParameterValue
Number of poles2
5SL4213-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage category3
5SL4213-8 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

The Siemens 5SL4213-8 is a SENTRON 5SL4 miniature circuit breaker — 2-pole, D-curve, 13 A, breaking 10 kA per both EN 60898 and IEC 60947-2 at 400 V AC. Rated voltage is 400 V AC, max multi-phase 440 V AC.

The 13 A D-curve is sized for a load that draws around 10–12 A steady but sees a short inrush — think a small compressor, a pump motor, or a bank of switching power supplies. Energy limiting class 3 tells you it restricts let-through energy, which helps with downstream component coordination. Terminals accept 0.75–25 mm² solid or stranded, tightened to 2.5–3 N·m. That covers most panel wiring up to 4 mm² comfortably, and the 25 mm² max lets you land a larger feeder if needed. The housing is 36 mm wide (2 width units,), 90 mm tall, 76 mm deep — standard DIN-rail footprint, no surprises. IP20 with conductors connected is normal for a panel-mounted MCB; it's not for wet locations.

Deployment context

Rated for ambient -25 to +55 °C and up to 95% humidity — fine for a ventilated electrical room or a weatherproof outdoor enclosure as long as it's IP-rated at the cabinet level. The sealable feature means you can lock the toggle to prevent unauthorized reset.

Frequently asked questions

How do I get pricing and availability for 5SL4213-8?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time — we source through independent distribution and quote to order.

What is the breaking capacity of 5SL4213-8?

10 kA per EN 60898 and also 10 kA per IEC 60947-2. That's the same rating under both standards, so it's suitable for residential and light industrial panels.

What wire sizes does the 5SL4213-8 accept?

Solid and stranded conductors from 0.75 mm² up to 25 mm². Tightening torque is 2.5 to 3 N·m.

Will 5SL4213-8 drop into a panel specified around 5SL6563-7BB without rewiring?

Both are 2-pole SENTRON 5SL MCBs on a 36 mm DIN-rail footprint, so the mechanical fit is the same. The difference is the rating — 5SL4213-8 is a 13 A D-curve; verify the load current and tripping characteristic match your circuit before swapping.