Siemens 5SL4216-6 — 2-Pole MCB (DIN Rail)

Siemens 5SL4216-6 SENTRON MCB, 2P B 16A 10kA

MPN5SL4216-6
Active

Siemens SENTRON 5SL4216-6 miniature circuit breaker, 2-pole, B-curve, 16 A, 10 kA breaking capacity per EN 60898 / IEC 60947-2, 400 V AC, 2 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4216-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4216-6 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL4216-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SL4216-6 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4216-6 — Environmental
ParameterValue
Pollution degree2
5SL4216-6 — Specifications
ParameterValue
According to EN 60898 rated value10 kA
Energy Limitation Class3

Product details

What it is and what the ratings mean for fit

The Siemens SENTRON 5SL4216-6 is a 2-pole miniature circuit breaker rated 16 A with a B tripping characteristic and a 10 kA breaking capacity per both EN 60898 and IEC 60947-2. That 10 kA at 400 V AC means it can safely interrupt a fault current up to 10 000 A without welding its contacts or cascading the fault upstream — a standard residential and light-commercial panel rating. The B-curve (3–5× In magnetic trip) is the go-to for general-purpose resistive and lighting loads where inrush is low; it keeps nuisance trips off the board compared to a C-curve on motor or transformer circuits. This part occupies 2 modular width units (36 mm wide). Mounting position is any.

Panel integration and accessories

The 5SL4216-6 accepts supplementary devices (auxiliary switches, shunt trips, alarm contacts) via the product extension slot on the right side — useful for remote status or emergency-off circuits without adding a separate relay. Sealable terminals are standard, so a panel builder can lock the cover after commissioning to prevent tampering. Halogen-free and silicon-free construction matters if the board goes into a cleanroom or a corrosive environment where outgassing is a concern. Installation depth is 70 mm. Power loss per pole at rated current in hot operating state is 1.8 W.

Frequently asked questions

What is the difference between the 5SL4216-6 and the 5SY5202-6?

Both are 2-pole B-curve 16 A MCBs with 10 kA breaking capacity, but the 5SY5202-6 is universal-current rated (AC/DC) with a higher DC voltage rating (440 V) and a higher pollution degree (3), making it the industrial variant. The 5SL4216-6 is the infrastructure/residential version.

MPN
5SL4216-6