Siemens 5SL4232-7 — 2-Pole MCB (DIN Rail)

Siemens 5SL4232-7 SENTRON MCB, 2P C-32 A, 10 kA

MPN5SL4232-7
Active

Siemens SENTRON 5SL4232-7, miniature circuit breaker, 2-pole, C-curve, 32 A, 10 kA breaking capacity per IEC/EN 60898 and IEC 60947-2, 400 V AC, 2 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4232-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4232-7 — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value400 V
5SL4232-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL4232-7 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4232-7 — Environmental
ParameterValue
Pollution degree2
5SL4232-7 — Specifications
ParameterValue
According to EN 60898 rated value10 kA
Energy Limitation Class3

Product details

The Siemens 5SL4232-7 is a 2-pole SENTRON miniature circuit breaker with a C-curve trip characteristic, rated 32 A at 400 V AC. It breaks fault currents up to 10 kA, certified to both EN 60898 and IEC 60947-2 — so it covers residential/infrastructure branch circuits and industrial panel feeder protection under the same device. The 36 mm width (2 modular units) snaps onto standard DIN rail; mounting position is unrestricted, and the 70 mm installation depth leaves clearance behind a shallow enclosure cover.

The C-curve means magnetic trip between 5× and 10× In — 160 to 320 A instantaneous — suited for moderate inrush loads like small motor starters, lighting banks, and transformer primaries where a B-curve would nuisance-trip. The 10 kA breaking capacity at 400 V AC is the maximum prospective fault current the breaker can safely interrupt; in a 10 kA SCCR panel, this breaker coordinates without needing an upstream current-limiting fuse for most branch circuits. Mechanical life is 10 000 cycles typical, adequate for a distribution board that sees infrequent switching; not rated for frequent motor-start duty.

Snap-on DIN rail mount, any orientation. Ambient range -40 to 75 °C covers outdoor telecom cabinets and unheated plant areas. Sealable for lockout/tagout compliance. Accepts supplementary devices like shunt trips or auxiliary contacts for remote status.

Frequently asked questions

How do I get current pricing and availability for 5SL4232-7?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

When sourcing 5SL4232-7, what's the closest functional second-source — 5SL4363-7?

The 5SL4363-7 is the 3-pole sibling in the same SENTRON C-curve 10 kA series. It occupies 54 mm (3 MW) versus 36 mm (2 MW) for the 2-pole 5SL4232-7. If your panel was wired for a 2-pole breaker, the 3-pole unit will not drop in without rewiring and a wider DIN-rail footprint. The 5SL4232-7 is the correct 2-pole fit.

What is 5SL4232-7's listed depth (76 mm) on this component line?

The overall depth is 76 mm; the installation depth behind the panel face is 70 mm.

What is 5SL4232-7's listed width (36 mm) on this component line?

The width is 36 mm, which corresponds to 2 modular width units (MW) on standard DIN rail.

Will 5SL4232-7 drop into a panel that was specified around 5SL4363-7 without rewiring?

No. The 5SL4232-7 is a 2-pole breaker (36 mm wide); the 5SL4363-7 is a 3-pole breaker (54 mm wide). The panel's DIN-rail space and wiring scheme for a 3-pole device would not accept the 2-pole unit without rework.