Siemens 5SL4250-8CC — 2-Pole MCB (DIN Rail)

5SL4250-8CC SENTRON MCB, 2-pole D 50 A, 400 V, 10 kA

MPN5SL4250-8CC
Active

Siemens SENTRON 5SL4250-8CC miniature circuit breaker, 2-pole, D tripping characteristic, 50 A rated at 400 V AC, 10 kA breaking capacity per EN 60898, 2 MW units wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4250-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4250-8CC — Electrical
ParameterValue
Number of poles2
5SL4250-8CC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SL4250-8CC — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4250-8CC — Environmental
ParameterValue
Pollution degree2

Product details

The Siemens SENTRON 5SL4250-8CC is a 2-pole miniature circuit breaker with a D tripping characteristic, rated 50 A at 400 V AC and a breaking capacity of 10 kA per EN 60898. Rated current derates with ambient temperature: 46.19 A at 40 °C, 44.17 A at 45 °C, 42.05 A at 50 °C, and 39.81 A at 55 °C. Mounting position is unrestricted — can be oriented vertically, horizontally, or flat against the rail.

Lifecycle and sourcing status

No official successor has been published. The part is a standard catalog item in the SENTRON portfolio, so lead times are typically consistent with Siemens' production schedules for this class.

Touch protection is integrated (finger-safe terminals).

Electrical ratings and coordination notes

Maximum operating voltage on multi-phase AC circuits is 440 V. Single-phase supply rated at 400 V AC. For DC circuits, the maximum rated voltage is 72 V — this is not a general-purpose DC breaker for higher-voltage battery banks or solar strings. The neutral conductor is not switched (2-pole design switches both phase conductors, no integral neutral pole). Suitable for 2-phase or single-phase 2-wire applications where both lines are protected. Suitability listed for residential buildings and infrastructure — standard distribution board installation. Not specifically rated for motor-starting duty beyond the D-curve's inrush tolerance; verify coordination with downstream contactors if used in a motor branch circuit.