Skip to main content
Siemens 5SL4263-7RC — 2-Pole MCB (DIN Rail)

SENTRON 5SL4263-7RC MCB, 2P C 63 A, 10 kA, 415 V AC

MPN5SL4263-7RC
Active

SENTRON miniature circuit breaker, 5SL4263-7RC, 2-pole, C-curve, 63 A, 10 kA at 415 V AC, 1 MW width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4263-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentResidential buildings/infrastructure
5SL4263-7RC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value415 V
5SL4263-7RC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL4263-7RC — Mechanical
ParameterValue
Modular width units1
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL4263-7RC — Environmental
ParameterValue
Pollution degree2
At 30 °C rated value63 A
5SL4263-7RC — Specifications
ParameterValue
At AC rated value63 A
According to EN 60898 rated value10 kA
With single-phase operation at AC rated value250 V
Energy Limitation Class3

Product details

The SENTRON 5SL4263-7RC is a 2-pole miniature circuit breaker with a C tripping characteristic, rated 63 A at 415 V AC and a breaking capacity of 10 kA per EN 60898. It occupies a single modular width (18 mm) on the DIN rail, so it fits tight panel layouts without crowding adjacent breakers. At 63 A it handles a substantial feeder or submain, not just a final subcircuit. Power loss per pole runs 5.4 W at rated current in the hot state — a figure to check for thermal buildup inside a densely packed enclosure, especially when multiple breakers are ganged.

Depth is 76 mm (70 mm behind the panel), width 18 mm (1 MW), height 90 mm. Halogen-free and silicon-free construction reduces toxic smoke and silicone contamination in sensitive environments.

Electrical Ratings & Compliance

Rated for AC only, 50/60 Hz, with a maximum operating voltage of 440 V in multi-phase operation and 250 V single-phase. The DC rating is limited to 72 V maximum — not a general-purpose DC breaker above that level.

Frequently asked questions

Where can I buy 5SL4263-7RC and how do I get a price?

This part is sourced and quoted to order against an RFQ through our independent distribution channel. Submit an RFQ to confirm current availability and pricing.

What is 5SL4263-7RC's listed depth and width?

Depth is 76 mm (70 mm behind the panel), width is 18 mm (one modular unit).

Will 5SL4263-7RC drop into a panel specified around 5SL4363-7 without rewiring?

Both are 2-pole, 63 A, C-curve MCBs with the same 18 mm width and DIN-rail mounting, so they share the same footprint and basic ratings. However, the 5SL4363-7 carries a higher breaking capacity (25 kA per EN 60898) and a 440 V rated voltage; verify that the 10 kA / 415 V rating of the 5SL4263-7RC meets your panel's fault-current and voltage requirements before substituting.

What compliance documentation does SENTRON provide for 5SL4263-7RC?

The manufacturer provides standard documentation including a datasheet, CE declaration of conformity, and environmental compliance (RoHS, REACH). Specific UL or IEC certificates should be verified at quote time.

MPN