Siemens 5SL4301-8CC — 3-Pole MCB (DIN Rail)

Siemens 5SL4301-8CC SENTRON MCB, 3-pole D 1 A, 10 kA

MPN5SL4301-8CC
Active

Siemens SENTRON 5SL series, miniature circuit breaker, 3-pole, D tripping characteristic, 1 A rated current, 10 kA breaking capacity per EN 60898 at 400 V AC, order code 5SL4301-8CC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4301-8CC — Identification
ParameterValue
Design / model code5SL4CC
Brand nameSENTRON
Number of poles3
Suitability for operationResidential buildings/infrastructure
5SL4301-8CC — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 6089810 kA
Overvoltage category3
IP protection classIP20, with connected conductors
5SL4301-8CC — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Rated frequency50 Hz
5SL4301-8CC — Mechanical
ParameterValue
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.25 mm²
Terminal tightening torque, min.0.75 mm²
SealableYes
5SL4301-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperature+55 °C, max. 95% humidity

Product details

What this 1 A D-curve MCB is for

The Siemens 5SL4301-8CC is a 3-pole miniature circuit breaker from the SENTRON 5SL family, rated 1 A with a D tripping characteristic and a 10 kA breaking capacity per EN 60898 at 400 V AC. The 3-pole construction switches all three phases simultaneously, so it fits three-phase sub-circuits in residential or light infrastructure panels.

Snaps onto standard DIN rail — 3 width units (54 mm wide) — and accepts conductors from 0.75 mm² up to 25 mm², which covers both control wiring and power feed-through in a distribution board.

The D-curve's magnetic trip threshold (10–20× In) means it holds through the inrush of a small control transformer or a 0.25 kW motor starting direct-on-line, but still clears a hard short. Rated frequency is 50 Hz; maximum multi-phase voltage is 440 V AC.

Frequently asked questions

What is the 5SL4301-8CC used for?

This 3-pole D-curve miniature circuit breaker is used to protect three-phase circuits with high inrush loads — small transformers, solenoid banks, or fractional-horsepower motors — where the steady-state current is 1 A per phase and the magnetic trip characteristic must avoid nuisance tripping on startup.

Where can I buy the 5SL4301-8CC?

We source the 5SL4301-8CC to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
5SL4301-8CC