Skip to main content
Siemens 5SL4302-6 — Miniature Circuit Breakers (MCB)

Siemens 5SL4302-6 SENTRON MCB, 3-pole B-curve 2A 400V 10kA

MPN5SL4302-6
Active

Siemens SENTRON 5SL4302-6, miniature circuit breaker, 3-pole, B-curve, 2 A, 400 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4302-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4302-6 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

What it is and what it does

The Siemens 5SL4302-6 is a 3-pole miniature circuit breaker from the SENTRON family, rated 2 A with a B-curve trip characteristic. It protects branch circuits against overload and short-circuit in residential and infrastructure panels, with a 10 kA breaking capacity at 400 V AC per both EN 60898 and IEC 60947-2. The B-curve means it trips between 3 and 5 times rated current — suited for resistive or general-purpose loads where inrush is low, like lighting or heater circuits.

Panel fit and mounting

Occupies 3 modular width units (54 mm) on a DIN rail, with a 76 mm depth and 70 mm installation depth. Mounts in any position. The IP20 rating applies only with connected conductors — standard for enclosed distribution boards. Sealable cover option is built in, and the housing is halogen-free and silicon-free, which matters if the panel is in a clean environment or near sensitive equipment.

Frequently asked questions

Where can I buy 5SL4302-6 and get a price?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Will 5SL4302-6 drop into a panel specified around 5SL4363-7 without rewiring?

Yes — both are 3-pole SENTRON MCBs with identical dimensions (76 mm depth, 54 mm width, 90 mm height), same DIN-rail mounting, same 10 kA breaking capacity at 400 V AC. The only difference is the trip curve: 5SL4302-6 is B-curve (2 A), while 5SL4363-7 is C-curve (63 A). The panel footprint and wiring are interchangeable.

What compliance documentation does Siemens provide for 5SL4302-6?

The breaker carries a 10 kA rating per EN 60898 and IEC 60947-2, is halogen-free and silicon-free, and is rated for overvoltage category III with pollution degree 2 — standard for fixed-installation distribution boards.

MPN
5SL4302-6