Skip to main content
Siemens 5SL4302-7CC — Miniature Circuit Breakers (MCB)

Siemens 5SL4302-7CC SENTRON MCB, 3P C 2A 10kA 400V

MPN5SL4302-7CC
Active

Siemens SENTRON 5SL4302-7CC miniature circuit breaker, 3-pole, C-curve, 2 A, 10 kA breaking capacity at 400 V AC, IP20 with connected conductors.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4302-7CC — Ratings
ParameterValue
Overvoltage categoryIII
5SL4302-7CC — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

Siemens 5SL4302-7CC — SENTRON 3-pole C-curve MCB, 2 A, 10 kA

The Siemens 5SL4302-7CC is a 3-pole miniature circuit breaker from the SENTRON 5SL series, rated 2 A with a C tripping characteristic and a 10 kA breaking capacity at 400 V AC per EN 60898. That 10 kA interrupting rating means it can clear a fault current up to 10,000 amps without welding its contacts or rupturing the enclosure — a standard requirement for residential and light-commercial panelboards where the prospective short-circuit current stays under that threshold.

Occupies 3 modular width units — 54 mm wide — and requires 70 mm of clear installation depth behind the panel surface. The 76 mm overall depth includes the housing and terminals; plan for front-access wiring clearance.

Rated for ambient temperatures from -40 °C to +75 °C, with a 95% humidity limit at +55 °C. Vibration resistance tested to 50 m/s² at 25–150 Hz per IEC 60068-2-6. Sealable — the toggle can be locked or sealed in the OFF position for lockout/tagout compliance.

Frequently asked questions

How do I get current pricing and availability for 5SL4302-7CC?

Submit an RFQ through the storefront. The part is sourced to order; pricing and stock levels are confirmed at quote time.

What is the depth of 5SL4302-7CC?

The overall depth is 76 mm. Installation depth behind the panel face is 70 mm.

What is the width of 5SL4302-7CC?

The width is 54 mm, which corresponds to 3 modular width units on a standard DIN rail.

Will 5SL4302-7CC drop into a panel specified around 5SL4363-7 without rewiring?

Yes — both are 3-pole 5SL series breakers with the same physical footprint (54 mm wide, 76 mm deep) and DIN-rail mounting. The difference is the current rating and curve; 5SL4363-7 is a 63 A C-curve, while this is 2 A C-curve. If the panel busbar and wiring are sized for 63 A, dropping in a 2 A breaker is electrically safe but will trip on the existing load. No rewiring of the busbar or DIN-rail position is needed.

MPN
5SL4302-7CC