Skip to main content
Siemens 5SL4302-8 — Miniature Circuit Breakers (MCB)

Siemens 5SL4302-8 SENTRON MCB, 3P D 2A, 400V 10kA

MPN5SL4302-8
Active

Siemens SENTRON 5SL4302-8, 3-pole miniature circuit breaker, D characteristic, 2 A rated current at 400 V AC, 10 kA breaking capacity, 3 MW units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4302-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4302-8 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens SENTRON 5SL4302-8 is a 3-pole miniature circuit breaker with a D tripping characteristic, rated 2 A at 400 V AC and breaking 10 kA under both EN 60898 and IEC 60947-2.

At 30 °C ambient it holds the full 2 A. Push the panel to 40 °C and you're down to 1.92 A; at 45 °C it's 1.88 A; at 55 °C it's 1.79 A.

It's 3 modular width units (54 mm wide), 90 mm tall, 76 mm deep with a 70 mm installation depth behind the panel face. IP20 with conductors connected, so it's meant for enclosed distribution boards, not washdown areas. Sealable, halogen-free, silicon-free — matters if the panel goes into a clean room or food processing environment where outgassing is a concern. Supplementary devices (aux contacts, shunt trips, alarm switches) can be added on the side.

Frequently asked questions

Where can I buy 5SL4302-8 and how is it quoted?

We source the 5SL4302-8 through independent distribution channels and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here because the market moves daily.

What is the breaking capacity of 5SL4302-8?

It's rated 10 kA per both EN 60898 and IEC 60947-2 at 400 V AC. That 10 kA is the maximum fault current it can safely interrupt — match it to your available fault current at the panel.

What does the D characteristic mean on this MCB?

The D curve trips magnetically at 10 to 20 times rated current (20 to 40 A for this 2 A unit). It's designed for loads with high inrush like small motors, transformers, or welding equipment — the short delay prevents nuisance trips on startup.

Will 5SL4302-8 drop into a panel specified for 5SL4363-7?

Not without checking your load. The 5SL4363-7 is a different amp rating and pole configuration — the 5SL4302-8 is 3-pole 2 A D-curve. Same SENTRON family, same DIN-rail footprint, but the current rating and protection curve must match the circuit design.