The 10 kA breaking capacity, certified to both EN 60898 and IEC 60947-2, tells you it can safely interrupt a fault current up to 10,000 A at 400 V without welding its contacts or cascading upstream. That's the figure that governs selectivity coordination with the upstream device. Operating temperature spans -40 to 75 °C, covering unheated utility rooms and outdoor enclosures in cold climates.
Siemens 5SL4304-7 SENTRON MCB, 3-pole C-curve 4A 10kA
Siemens SENTRON miniature circuit breaker, 5SL4304-7, 3-pole, C-curve, 4 A, 400 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2.
Specifications
| Parameter | Value |
|---|---|
| Brand name | SENTRON |
| Number of poles | 3 |
| Pole configuration | 3P |
| Suitability for operation | Residential buildings/infrastructure |
| Parameter | Value |
|---|---|
| Tripping characteristic (curve) | C |
| Breaking capacity per EN 60898 | 10 kA |
| Breaking capacity per IEC 60947-2 | 10 kA |
| Overvoltage category | III |
| IP protection class | IP20, with connected conductors |
| Energy limitation class | 3 |
| Pollution degree | 2 |
| Parameter | Value |
|---|---|
| Rated voltage (AC, multi-phase) | 440 V |
| Voltage type (AC/DC) | AC |
| Supply frequency range | 50/60 Hz |
| Power loss per pole at rated current (AC, hot) | 1.2 W |
| Mechanical service life (operating cycles, typ.) | 10 000 |
| Parameter | Value |
|---|---|
| Modular width units | 3 |
| Mounting position | any |
| Width | 54 mm |
| Height | 90 mm |
| Depth | 76 mm |
| Installation depth | 70 mm |
| Terminal tightening torque, max. | 75 °C |
| Terminal tightening torque, min. | -40 °C |
| Sealable | Yes |
| Accepts supplementary devices | Yes |
| Parameter | Value |
|---|---|
| Halogen-free | Yes |
| Silicone-free | Yes |
Product details
Frequently asked questions
How do I get current pricing and availability for 5SL4304-7?
The 5SL4304-7 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.
What is the closest functional second-source for 5SL4304-7?
The peer 5SL4363-7 shares the same SENTRON family, 3-pole C-curve design, 400 V AC rating, and 10 kA breaking capacity. The difference is the current rating — 5SL4363-7 is a 63 A unit versus the 4 A of 5SL4304-7. Panel footprint (76 mm depth, 54 mm width, 90 mm height) and DIN-rail mounting are identical, so it drops into the same enclosure without rewiring the busbar layout.
What is 5SL4304-7's listed depth?
The 5SL4304-7 has a depth of 76 mm, an installation depth of 70 mm, a width of 54 mm (3 modular units), and a height of 90 mm.
What compliance documentation does this brand provide for 5SL4304-7?
The 5SL4304-7 is halogen-free and silicon-free. It carries a degree of pollution 2 rating and overvoltage category III. The breaking capacity is certified to both EN 60898 and IEC 60947-2. The product is sealable for tamper-proof installations.