Skip to main content
Siemens 5SL4310-7 — 3-Pole MCB (DIN Rail)

Siemens 5SL4310-7 SENTRON MCB, 3P C 10A 10kA

MPN5SL4310-7
Active

Siemens SENTRON 5SL4310-7 miniature circuit breaker, 3-pole, C-curve, 10 A, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 400 V AC, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4310-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4310-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4310-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.9 W
Mechanical service life (operating cycles, typ.)10 000
5SL4310-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL4310-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what the ratings mean

The Siemens SENTRON 5SL4310-7 is a 3-pole miniature circuit breaker with a C-curve trip characteristic, rated 10 A at 400 V AC. The C-curve means it trips between 5 and 10 times rated current — standard for mixed resistive and moderate inductive loads like lighting, small motor circuits, and general-purpose branch protection in residential and infrastructure panels. The 10 kA breaking capacity, certified to both EN 60898 and IEC 60947-2, tells you it can safely interrupt a fault current up to 10 kA without welding or exploding. That's the figure that governs your SCCR coordination downstream.

Panel integration and mounting

Occupies 3 modular width units (54 mm) on a DIN rail. Depth is 76 mm (70 mm installation depth). Mount in any position — no derating needed for orientation. IP20 with connected conductors, so it's fine inside a closed panel but not for wet or dust-exposed locations. Sealable cover is standard; halogen-free and silicon-free construction matters if the panel is in a clean-room or food-processing environment where outgassing is a concern.

Frequently asked questions

Where can I buy 5SL4310-7 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SL4310-7 drop into a panel that was specified around 5SL4363-7 without rewiring?

Yes — both are 3-pole SENTRON MCBs with identical dimensions (76 mm depth, 54 mm width, 90 mm height) and the same 3-modular-width footprint, so the mechanical swap is direct. The difference is the current rating: 5SL4310-7 is 10 A, while 5SL4363-7 is 63 A. Verify the branch load before substituting.

What compliance documentation does this brand provide for 5SL4310-7?

The SENTRON series carries standard certifications for EN 60898 and IEC 60947-2. The part is halogen-free and silicon-free; check the manufacturer's declaration for RoHS/REACH status on the specific batch.

MPN
5SL4310-7