Siemens SENTRON 5SL4310-8 miniature circuit breaker, 3-pole, D tripping characteristic, 10 A, 400 V AC, 10 kA breaking capacity per EN 60898 / IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4310-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4310-8 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL4310-8 is a SENTRON-series miniature circuit breaker — 3-pole, D-curve, rated 10 A at 400 V AC with a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. The D characteristic means it tolerates inrush currents up to 10–20× the rated current before tripping, which makes it the right choice for motor starters, transformers, and other inductive loads that draw a heavy start-up surge.

The 10 kA rating under both EN 60898 (household standard) and IEC 60947-2 (industrial standard) means this breaker can safely interrupt fault currents up to 10 000 A at 400 V without welding its contacts or cascading the fault upstream. That dual certification covers residential infrastructure and light commercial panels. Maximum operating voltage sits at 440 V AC for multi-phase operation, giving a bit of headroom above the nominal 400 V.

Physical integration and environment

Dimensions: 90 mm high, 54 mm wide (3 MW), 76 mm deep, with a 70 mm installation depth into the panel. Sealable with a lead or tag for tamper-proof metering or safety isolation. Supplementary devices (shunt trips, auxiliary contacts, alarm switches) can be snapped onto the right side without extra wiring space.

Frequently asked questions

What is the difference between 5SL4310-8 and 5SL4363-7?

Both are 3-pole SENTRON MCBs with the same physical footprint (54 mm wide, 76 mm deep), same 10 kA breaking capacity, and same voltage ratings. The difference is the tripping curve: 5SL4310-8 uses a D-curve (10–20× In, for motor/transformer loads), while 5SL4363-7 uses a C-curve (5–10× In, for general-purpose and resistive loads). They share the same mechanical service life (10 000 cycles) and both accept supplementary devices.

What is the breaking capacity of 5SL4310-8?

10 kA per both EN 60898 and IEC 60947-2 at 400 V AC, 50/60 Hz.

Where can I source 5SL4310-8?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing confirmed at quote time.

MPN