Skip to main content
Siemens 5SL4310-8 — 3-Pole MCB (DIN Rail)

Siemens 5SL4310-8 SENTRON MCB, 3P D 10A 10kA

MPN5SL4310-8
Active

Siemens SENTRON 5SL4310-8 miniature circuit breaker, 3-pole, D tripping characteristic, 10 A, 400 V AC, 10 kA breaking capacity per EN 60898 / IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4310-8 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4310-8 — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4310-8 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.9 W
Mechanical service life (operating cycles, typ.)10 000
5SL4310-8 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL4310-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4310-8 is a SENTRON-series miniature circuit breaker — 3-pole, D-curve, rated 10 A at 400 V AC with a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. The D characteristic means it tolerates inrush currents up to 10–20× the rated current before tripping, which makes it the right choice for motor starters, transformers, and other inductive loads that draw a heavy start-up surge.

The 10 kA rating under both EN 60898 (household standard) and IEC 60947-2 (industrial standard) means this breaker can safely interrupt fault currents up to 10 000 A at 400 V without welding its contacts or cascading the fault upstream. That dual certification covers residential infrastructure and light commercial panels. Maximum operating voltage sits at 440 V AC for multi-phase operation, giving a bit of headroom above the nominal 400 V.

Physical integration and environment

Dimensions: 90 mm high, 54 mm wide (3 MW), 76 mm deep, with a 70 mm installation depth into the panel. Sealable with a lead or tag for tamper-proof metering or safety isolation. Supplementary devices (shunt trips, auxiliary contacts, alarm switches) can be snapped onto the right side without extra wiring space.

Frequently asked questions

What is the difference between 5SL4310-8 and 5SL4363-7?

Both are 3-pole SENTRON MCBs with the same physical footprint (54 mm wide, 76 mm deep), same 10 kA breaking capacity, and same voltage ratings. The difference is the tripping curve: 5SL4310-8 uses a D-curve (10–20× In, for motor/transformer loads), while 5SL4363-7 uses a C-curve (5–10× In, for general-purpose and resistive loads). They share the same mechanical service life (10 000 cycles) and both accept supplementary devices.

What is the breaking capacity of 5SL4310-8?

10 kA per both EN 60898 and IEC 60947-2 at 400 V AC, 50/60 Hz.

Where can I source 5SL4310-8?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing confirmed at quote time.

MPN
5SL4310-8