Skip to main content
Siemens 5SL4313-7 — Miniature Circuit Breakers (MCB)

Siemens 5SL4313-7 SENTRON MCB, 3P C13, 10 kA, 400 V

MPN5SL4313-7
Active

Siemens SENTRON 5SL4 series miniature circuit breaker, 3-pole, 13 A rated current, C tripping characteristic, 10 kA breaking capacity, 400 V AC, 3 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4313-7 — Ratings
ParameterValue
Overvoltage category3
5SL4313-7 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The 5SL4313-7 is a 3-pole miniature circuit breaker rated 13 A at 400 V AC with a C tripping characteristic — meaning it handles moderate inrush (5–10× rated current) typical of motor and lighting loads in residential and infrastructure panels. The 10 kA breaking capacity, certified to both EN 60898 and IEC 60947-2, means it safely clears a fault up to 10 kA without upstream protection needing to intervene; at that level the arc is quenched inside the 3-width-unit housing.

Physical fit and wiring constraints

Terminal capacity accepts solid or stranded conductors from 0.75 mm² up to 25 mm², with a tightening torque range of 2.5 to 3 N·m. Ambient temperature range of -25 to +55 °C and IP20 protection (with connected conductors) suit standard indoor electrical rooms and distribution boards.

The 5SL4313-7 is designed to EN 60898 and IEC 60947-2 for breaking capacity, overvoltage category 3, and energy limiting class 3. It is halogen-free and silicon-free, sealable, and rated for any mounting position. Suitability is marked for residential buildings and infrastructure — not for neutral conductor switching (no neutral pole).

Frequently asked questions

How do I get current pricing and availability for the 5SL4313-7?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the 5SL4313-7's depth?

The total depth is 76 mm, with an installation depth of 70 mm.

What conductor sizes does the 5SL4313-7 accept?

The screw terminals accept solid or stranded conductors from 0.75 mm² up to 25 mm².

Will the 5SL4313-7 drop into a panel specified around the 5SL3625-7MB without rewiring?

Both are 3-pole SENTRON MCBs on the same DIN-rail footprint and use the same terminal range (0.75–25 mm²), so the 5SL4313-7 is a direct mechanical and wiring replacement — no rewiring needed. However, the 5SL4313-7 is rated 13 A C-curve, so verify the circuit's load and tripping requirements match.

MPN
5SL4313-7