Skip to main content
Siemens 5SL4315-7 — 3-Pole MCB (DIN Rail)

Siemens 5SL4315-7 SENTRON MCB, 3P C 1.6A 10kA 400V

MPN5SL4315-7
Active

Siemens SENTRON 5SL4315-7 miniature circuit breaker, 3-pole, C-curve, 1.6 A, 10 kA breaking capacity at 400 V AC, 3 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4315-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4315-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4315-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.3 W
Mechanical service life (operating cycles, typ.)10 000
5SL4315-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL4315-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

At 1.6 A it protects a branch circuit drawing about 0.7 kVA at 400 V three-phase. Breaking capacity of 10 kA at 400 V AC (per EN 60898 and IEC 60947-2) covers most residential and light commercial service-entrance fault levels in European 400/230 V networks. The 3-pole design switches all three phases simultaneously, which matters for three-phase motor or distribution subfeeds. Rated for 50/60 Hz supply, maximum operating voltage 440 V AC multi-phase, and DC rated up to 72 V.

Snap-on DIN rail mount, any position. Sealable with a lead seal or lockable cover — useful for utility-metered or tamper-evident circuits.

Frequently asked questions

What is the breaking capacity of 5SL4315-7?

10 kA at 400 V AC under both EN 60898 and IEC 60947-2 — the same rating for residential and industrial fault-current duty.

Will 5SL4315-7 drop into a panel specified around 5SL4363-7?

Yes — same 3-pole C-curve footprint, same 54 mm width, same 76 mm depth, same DIN-rail mounting. The only difference is the current rating: 1.6 A vs 63 A on the 5SL4363-7. No rewiring or panel modification needed if the branch circuit load matches the lower rating.

Where can I buy 5SL4315-7?

Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing confirmed at quote time.

MPN