Siemens 5SL4315-8 — 3-Pole MCB (DIN Rail)

Siemens 5SL4315-8 SENTRON MCB, D Curve, 1.6 A, 3P, 10 kA

MPN5SL4315-8
Active

Siemens SENTRON 5SL4315-8, 3-pole miniature circuit breaker, D tripping characteristic, 1.6 A rated current, 10 kA breaking capacity per EN 60898 and IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4315-8 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Suitability for operationResidential buildings/infrastructure
5SL4315-8 — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4315-8 — Electrical
ParameterValue
Rated current (AC)1.6 A
Rated voltage (AC, multi-phase)440 V
5SL4315-8 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL4315-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperature+55 °C, max. 95% humidity

Product details

The Siemens 5SL4315-8 is a SENTRON miniature circuit breaker (MCB) with a D tripping characteristic, rated 1.6 A at 400 V AC across three poles. The D curve means it tolerates high inrush currents — typically motor or transformer loads — without nuisance tripping, while still clearing faults at the rated 10 kA breaking capacity per EN 60898 and IEC 60947-2.

Rated current is 1.6 A at 30 °C, but the thermal derating curve is published: 1.54 A at 40 °C, 1.5 A at 45 °C, and 1.43 A at 55 °C. If the panel ambient runs hot, that 1.43 A figure is the one to size against — not the 30 °C number. The breaker is rated for 440 V AC maximum in multi-phase operation, and 72 V DC maximum.

Sealable, halogen-free, silicon-free, with touch protection on the terminals.

Frequently asked questions

What is the breaking capacity of 5SL4315-8?

10 kA per EN 60898 and also 10 kA per IEC 60947-2 at 400 V AC.

What is the D tripping characteristic used for?

The D curve tolerates high inrush currents typical of motor or transformer loads, so it avoids nuisance tripping on startup while still clearing faults at the rated 10 kA.

Where can I buy 5SL4315-8?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SL4315-8