Siemens 5SL4316-6 — 3-Pole MCB (DIN Rail)

Siemens 5SL4316-6 SENTRON MCB, 3P B-curve 16A 10kA

MPN5SL4316-6
Active

Siemens SENTRON 5SL4316-6 miniature circuit breaker, 3-pole, B-curve, 16 A, 400 V AC, 10 kA breaking capacity, 3 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4316-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4316-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4316-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.8 W
Mechanical service life (operating cycles, typ.)10 000
5SL4316-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL4316-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL4316-6 is a 3-pole miniature circuit breaker rated 16 A with a B tripping characteristic, designed for 400 V AC systems at 50/60 Hz. The B-curve (3–5× In instantaneous trip) suits resistive and lighting loads where inrush is low; for motor or transformer circuits you would reach for a C-curve sibling like the 5SL4363-7. Halogen-free and silicon-free molding suits environments where outgassing matters, such as HVAC or clean-build panels. Power loss per pole is 1.8 W at rated current in hot operating state, so a 3-pole unit dissipates roughly 5.4 W — factor into enclosure thermal rise if you are packing several breakers in a sealed box.

Frequently asked questions

What is the difference between 5SL4316-6 and 5SL4363-7?

Both are 3-pole SENTRON MCBs with the same 400 V AC, 10 kA rating, dimensions (76×54×90 mm), and 10 000-cycle mechanical life. The 5SL4316-6 uses a B-curve (3–5× In) for resistive/lighting loads; the 5SL4363-7 uses a C-curve (5–10× In) for moderate inrush loads like small motors or transformers. They are mechanically interchangeable in the same DIN-rail panel if the trip curve matches the circuit.

What is the depth of 5SL4316-6?

The depth is 76 mm; installation depth is 70 mm. Width is 54 mm (3 modular units), height is 90 mm.

Where can I buy 5SL4316-6?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

MPN