Siemens 5SL4316-8 — 3-Pole MCB (DIN Rail)

Siemens 5SL4316-8 SENTRON MCB, 3P D 16A 400V 10kA

MPN5SL4316-8
Active

Siemens SENTRON miniature circuit breaker, 3-pole, D-characteristic, 16 A, 400 V AC, 10 kA breaking capacity per EN 60898 / IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4316-8 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4316-8 — Protection
ParameterValue
Tripping characteristic (curve)D
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4316-8 — Electrical
ParameterValue
Rated current (AC)16 A
Rated voltage (AC, multi-phase)440 V
5SL4316-8 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL4316-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL4316-8 is a 3-pole miniature circuit breaker (MCB) with a D tripping characteristic, rated 16 A at 400 V AC and a 10 kA breaking capacity per EN 60898 and IEC 60947-2.

At 40 °C it derates to 14.78 A, at 45 °C to 14.08 A, and at 55 °C to 12.74 A.

Sourcing and fit

This MCB is specified for residential buildings and infrastructure per the manufacturer's suitability listing. It is a standard SENTRON 5SL-series device, so it shares the same DIN-rail footprint, busbar comb, and terminal accessories as the rest of the 5SL family. If you are replacing a 5SL4363-7 (a 63 A D-curve 3-pole), the 5SL4316-8 drops into the same panel slot with the same wiring — just match the amp rating to your load. For current pricing and availability, send an RFQ; we source through independent distribution and confirm at quote time.

Frequently asked questions

What is the breaking capacity of 5SL4316-8?

10 kA per EN 60898 and IEC 60947-2 at 400 V AC.

What is the tripping characteristic of 5SL4316-8?

D-curve — designed for loads with high inrush, like motors or transformers.

Will 5SL4316-8 fit in a panel designed for 5SL4363-7?

Yes, same 3-pole DIN-rail footprint, same 54 mm width, same 76 mm depth — the only difference is the amp rating.

Where can I buy 5SL4316-8?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
5SL4316-8