Siemens 5SL4340-6 — Miniature Circuit Breakers (MCB)

Siemens 5SL4340-6 SENTRON MCB, 3P 40A B-curve 10kA

MPN5SL4340-6
Active

Siemens SENTRON 5SL4340-6, miniature circuit breaker, 3-pole, B characteristic, 40 A, 400 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2.

$84.99 – $95.34Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4340-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SL4340-6 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL4340-6 is a SENTRON 3-pole miniature circuit breaker rated 40 A with a B tripping characteristic, designed for 400 V AC systems and a 10 kA breaking capacity under both EN 60898 and IEC 60947-2.

The B-curve trips between 3 and 5 times rated current (120–200 A for this 40 A unit), making it the right choice for resistive and general-purpose loads where inrush is modest — lighting circuits, socket outlets, small heaters. It is not intended for motor starting or transformer primary protection where higher inrush would nuisance-trip a B-curve; that is what a C or D characteristic handles. Rated for 400 V AC three-phase (440 V max multi-phase) and 50/60 Hz, it covers standard European LV distribution. The 10 kA breaking capacity is the same under both EN 60898 (household-type) and IEC 60947-2 (industrial-type) standards — no derating needed between the two test regimes. Mechanical life rated at 10 000 operating cycles typical.

Physical fit and integration

Sealable, halogen-free, and silicon-free construction — useful for installations requiring low-smoke zero-halogen cabling or where silicone outgassing could contaminate sensitive contacts (e.g., relay or PLC environments).

Frequently asked questions

Will 5SL4340-6 drop into a panel specified around 5SL4363-7 without rewiring?

Yes — the two breakers share identical dimensions (76 mm depth, 54 mm width, 90 mm height), mounting position, and 3-pole form factor. The only functional difference is the tripping characteristic: the 5SL4340-6 is a B-curve (3–5× In), while the 5SL4363-7 is a C-curve (5–10× In). If the panel was designed for a C-curve, swapping to a B-curve may cause nuisance tripping on loads with moderate inrush (small motors, transformers). Check the load type before substituting.

MPN
5SL4340-6