Siemens 5SL4340-8 — 3-Pole MCB (DIN Rail)

Siemens 5SL4340-8 SENTRON MCB, 3P D 40A 10kA

MPN5SL4340-8
Active

Siemens SENTRON 5SL4340-8 miniature circuit breaker, 3-pole, D-curve, 40 A, 400 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4340-8 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4340-8 — Protection
ParameterValue
Tripping characteristic (curve)D
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4340-8 — Electrical
ParameterValue
Rated current (AC)40 A
Rated voltage (AC, multi-phase)440 V
5SL4340-8 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SL4340-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4340-8 is a SENTRON miniature circuit breaker (MCB) — 3-pole, D-tripping characteristic, rated 40 A at 400 V AC, with a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. That dual-standard rating means it covers residential/infrastructure panelboards (EN 60898) and industrial feeder circuits (IEC 60947-2) under one order code, simplifying your BOM for mixed-duty panels. D-curve tripping (10–20× In) is the right choice for transformer inrush, motor starting, or any load with a high short-duration surge — the magnetic trip holds off nuisance trips while still clearing a hard fault within the 10 kA SCCR. At 40 A this MCB handles a 15–20 kW three-phase motor or a lighting/distribution subfeed. Rated current derates with ambient temperature: 40 A at 30 °C, 37.89 A at 40 °C, 36.8 A at 45 °C, 34.47 A at 55 °C. In a warm enclosure (say 45 °C internal) the effective continuous rating drops to 36.8 A — size your upstream protection accordingly.

IP20 with conductors connected — fine for enclosed panels, not for wet-area standalone use. Mounting position any, so it can be installed horizontally or vertically inside a cabinet without derating. Overvoltage category III (distribution-level), pollution degree 2 (normal industrial/ commercial environment). Sealable terminals available — required for utility-metering or revenue-grade panels where tamper evidence is mandatory. Mechanical life 10 000 switching cycles typical — adequate for a protection device that operates infrequently (fault clearing or manual isolation), not a daily-switched load-break device.

Selectivity & Coordination

Energy limitation class 3 means this MCB limits let-through energy enough to coordinate with downstream branch breakers in most residential and light-commercial panelboards. The 5SL4340-8 is a 3-pole device switching all phases — it breaks all three poles simultaneously on a fault on any phase, which is standard for three-phase subfeeds and motor circuits. Do not use it for single-phase branch protection unless you are comfortable with an unswitched neutral.

Frequently asked questions

Will the 5SL4340-8 drop into a panel specified for the 5SL4363-7 without rewiring?

The 5SL4340-8 and 5SL4363-7 share the same SENTRON 5SL platform — same 3-pole DIN-rail footprint, same 54 mm width (3 MW). The deciding difference is the trip curve and rating: the 5SL4340-8 is a D-curve 40 A, while the 5SL4363-7 is a different curve/rating. If the panel was wired for a 3-pole 40 A D-curve, the 5SL4340-8 drops in without rewiring. Verify the original order code's rating and curve against your load before committing.

MPN
5SL4340-8