Skip to main content
Siemens 5SL4363-6 — 3-Pole MCB (DIN Rail)

Siemens 5SL4363-6 SENTRON MCB, 3P, B-Curve, 63 A, 10 kA

MPN5SL4363-6
Active

Siemens SENTRON 5SL4363-6, miniature circuit breaker, 3-pole, B-curve, 63 A, 400 V AC, 10 kA breaking capacity per IEC 60898 / 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4363-6 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationResidential buildings/infrastructure
5SL4363-6 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-210 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SL4363-6 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)5 W
Mechanical service life (operating cycles, typ.)10 000
5SL4363-6 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
Accepts supplementary devicesYes
5SL4363-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL4363-6 is a 3-pole miniature circuit breaker (MCB) rated for 63 A at 400 V AC, with a B tripping characteristic and a 10 kA breaking capacity certified to both EN 60898 and IEC 60947-2. The B-curve trips between 3 and 5 times rated current (roughly 189–315 A for this 63 A unit), making it the right choice for resistive loads and general-purpose lighting circuits where inrush is modest. On a 400 V three-phase supply, the breaker handles line-to-line faults up to 440 V maximum, and the 50/60 Hz rating covers both mains frequencies without derating.

Frequently asked questions

What is the breaking capacity of the 5SL4363-6?

The 5SL4363-6 carries a 10 kA breaking capacity under both EN 60898 and IEC 60947-2, so it safely interrupts faults up to 10 000 A.

What is the difference between the 5SL4363-6 and the 5SL4363-7?

The 5SL4363-7 is identical in every dimension, pole count, voltage rating, and breaking capacity — the only difference is the trip characteristic: the -6 is B-curve (3–5× In), the -7 is C-curve (5–10× In). They are physically interchangeable in the same panel.

Where can I buy the 5SL4363-6?

The 5SL4363-6 is sourced and quoted to order against an RFQ through independent distribution. Contact us for current pricing and availability.

MPN
5SL4363-6