Siemens 5SL4402-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL4402-6 SENTRON MCB, 4P B-Curve 2 A, 10 kA

MPN5SL4402-6
Active

Siemens SENTRON miniature circuit breaker, 4-pole B-curve, 2 A rated at 400 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2, order code 5SL4402-6.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4402-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4402-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC2 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL4402-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SL4402-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4402-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity

Product details

At 2 A this MCB protects a 2 A branch circuit; derate to 1.92 A at 40 °C and 1.79 A at 55 °C if the panel runs warm. The 4-pole configuration switches all four lines —, L2, L3, and N — with no neutral switching, meaning the neutral pole is a switched pole but not a fused function. The 10 kA SCCR is the same under both EN and IEC standards, so it meets the common grid fault level for most commercial sub-distribution boards.

Touch protection is built in.

The SENTRON series is a standard Siemens MCB line, so documentation (declaration of conformity, RoHS, REACH) is available on request for your quality pack.

Frequently asked questions

What is the breaking capacity of 5SL4402-6?

It is rated 10 kA under both EN 60898 and IEC 60947-2, matching the standard fault level for most commercial sub-distribution.

Will 5SL4402-6 drop into a panel specified around 5SL3640-7MB without rewiring?

The 5SL4402-6 is a 4-pole B-curve 2 A MCB, while the 5SL3640-7MB is a different variant — check the pole count, current rating, and tripping characteristic of the existing part before swapping. Footprint (DIN rail, 4 MW) is the same, but the electrical ratings must match the circuit design.

Where can I buy 5SL4402-6?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.