Siemens 5SL4402-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL4402-7 SENTRON MCB, 4P C-Curve 2A, 10kA 400V

MPN5SL4402-7
Active

Siemens SENTRON 5SL4402-7, 4-pole miniature circuit breaker, C-curve, 2 A rated, 10 kA breaking capacity at 400 V AC, 4 MWU.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4402-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4402-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC2 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL4402-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4402-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4402-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4402-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens SENTRON 5SL4402-7 is a 4-pole miniature circuit breaker (MCB) with a C-curve trip characteristic, rated 2 A at 400 V AC and a 10 kA breaking capacity per EN 60898 and IEC 60947-2. It's built for residential and infrastructure branch-circuit protection — think lighting, socket outlets, and small loads where the inrush isn't severe but you still need a solid short-circuit interrupt.

The C-curve (5-10x In) means it holds through motor and capacitive inrush but trips fast on a hard fault. At 2 A, it's sized for smaller final circuits, not main feeders. The maximum operating voltage for multi-phase operation is 440 V AC, so it's comfortable on 400 V three-phase panels with some headroom. Thermal derating is published: at 40 °C ambient it carries 1.92 A, at 45 °C it's 1.88 A, and at 55 °C it drops to 1.79 A. If the panel runs hot, factor that in. Sealable, halogen-free, and silicon-free construction.

Frequently asked questions

What is the breaking capacity of the 5SL4402-7?

The 5SL4402-7 has a 10 kA breaking capacity at 400 V AC per both EN 60898 and IEC 60947-2 standards.

Where can I buy the 5SL4402-7 and how is it quoted?

The 5SL4402-7 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no firm stock or price is published here.

Will the 5SL4402-7 drop into a panel specified for 5SL4106-7CC?

Both are 4-pole SENTRON MCBs with the same 4 MWU footprint, but the 5SL4106-7CC is a B-curve 6 A device while the 5SL4402-7 is a C-curve 2 A device. Mechanically interchangeable on the DIN rail; the trip curve and rating difference means a circuit-design review, not a straight swap.