Skip to main content
Siemens 5SL4506-6 — 1-Pole MCB (DIN Rail)

Siemens 5SL4506-6 SENTRON MCB, 6A 10kA B-Curve 1P+N

MPN5SL4506-6
Active

Siemens SENTRON 5SL4506-6 miniature circuit breaker, 230 V AC, 10 kA, 1P+N, B-curve, 6 A.

$10.67Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4506-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL4506-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SL4506-6 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4506-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4506-6 is a SENTRON miniature circuit breaker (MCB) rated 6 A with a B tripping characteristic, 10 kA breaking capacity per EN 60898 and IEC 60947-2, and a 1P+N pole configuration for 230 V AC single-phase circuits. The B-curve means it trips at 3–5× rated current, suited for resistive and general-purpose loads where inrush is modest — lighting, small appliances, and control transformers in residential or light commercial infrastructure panels.

Panel fit and integration

Occupies 2 modular width units (36 mm) on a DIN rail, with a depth of 76 mm and installation depth of 70 mm. Mounting position is unrestricted. IP20 with connected conductors — suitable for enclosed distribution boards. The housing is halogen-free and silicon-free, and the unit is sealable for tamper-proof installations. Supplementary devices (auxiliary switches, shunt trips, alarm contacts) can be added on the side.

Frequently asked questions

What are the key ratings of the 5SL4506-6?

6 A rated current, B-curve (trips at 3–5× In), 10 kA breaking capacity per EN 60898 and IEC 60947-2, 230 V AC single-phase, 1P+N poles, 2 modular width units (36 mm).

Where can I buy the 5SL4506-6?

Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL4506-6 drop into a panel specified around the 5SL4363-7?

No — the 5SL4363-7 is a 3-pole, 3-module-width (54 mm) C-curve breaker at 400 V AC, while the 5SL4506-6 is a 1P+N, 2-module-width (36 mm) B-curve unit at 230 V. The footprint, pole count, and voltage ratings differ, so direct swap without rewiring is not possible.

What compliance documentation does Siemens provide for the 5SL4506-6?

The 5SL4506-6 carries ratings per EN 60898 and IEC 60947-2, with IP20 protection, overvoltage category III, and pollution degree 2. The halogen-free and silicon-free construction supports environmental compliance requirements typical for residential and infrastructure installations.

MPN
5SL4506-6