Siemens 5SL4506-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL4506-7 SENTRON MCB, 6A C-Curve, 1P+N, 10kA

MPN5SL4506-7
Active

Siemens SENTRON 5SL4506-7 miniature circuit breaker, 1P+N, C-curve, 6 A, 230 V AC, 10 kA breaking capacity, 2 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4506-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL4506-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL4506-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4506-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4506-7 is a SENTRON miniature circuit breaker rated 6 A with a C-curve tripping characteristic, 1P+N pole configuration, and a 10 kA breaking capacity per both EN 60898 and IEC 60947-2.

The 90 mm height and 36 mm width are standard for a 1P+N MCB in a DIN-rail enclosure — no surprises for the panel builder laying out the gland plate. Mounting position is unrestricted; the breaker can be oriented any way the cabinet layout demands. IP20 protection with connected conductors — standard for a distribution board interior.

Breaking capacity is 10 kA under both EN 60898 (household and similar installations) and IEC 60947-2 (industrial switchgear). That dual-rated 10 kA figure is the same for both standards — no derating needed when moving from a residential to a light-industrial application, as long as the prospective fault current stays at or below 10 kA. Power loss is 1.6 W per pole in hot operating state at rated current. For a 1P+N breaker that means 1.6 W total dissipation — negligible for thermal budgeting inside a distribution board, but worth noting if you are packing many breakers into a small enclosure with limited ventilation. DC rated maximum is 72 V — usable on DC control circuits at that voltage, but the 10 kA breaking capacity applies to AC only; DC interrupting performance is not specified here.

Pollution degree 2 (non-conductive pollution with occasional condensation) and overvoltage category III (equipment in fixed installations with high transient overvoltages) — standard for distribution boards downstream of the utility meter.

Frequently asked questions

Will 5SL4506-7 drop into a panel specified around 5SL4363-7 without rewiring?

Not directly. The 5SL4363-7 is a 3-pole (3P) breaker, 54 mm wide (3 MW units), rated 400 V AC. The 5SL4506-7 is 1P+N, 36 mm wide (2 MW units), rated 230 V AC. The footprint and voltage differ — the panel would need re-wiring and a different DIN-rail layout.

MPN