Siemens 5SL4510-7CC SENTRON MCB, 1P+N, C-curve, 10 A, 10 kA

MPN5SL4510-7CC
Active

Siemens SENTRON 5SL4510-7CC miniature circuit breaker, 1P+N, C-curve, 10 A rated current, 10 kA breaking capacity per EN 60898, 230 V AC, 2 width units (36 mm), IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4510-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL4510-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)10 kA
Overvoltage category3
5SL4510-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL4510-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

Integrator note — 5SL4510-7CC

The Siemens SENTRON 5SL4510-7CC is a 1P+N miniature circuit breaker rated 10 A with a C tripping characteristic and a 10 kA breaking capacity per EN 60898 at 230 V AC. Neutral is switched internally, so the part covers both phase and neutral in a single 2-MW (36 mm) package.

Selectivity and coordination

Energy limiting class 3 means this MCB lets through less energy under fault, improving selectivity with downstream C-curve breakers of lower rating. The 10 kA SCCR at 230 V AC matches the typical service entrance rating for residential/infrastructure panels. For a BOM line requiring 10 A protection with neutral switching, the 5SL4510-7CC is the direct fit; the 5SL4120-7CC (same physical footprint, 2 MW, 1P+N) carries a 20 A rating with the same C-curve and 10 kA — the only difference is the overload threshold. No rewiring needed to swap between them at the same current level.

Panel integration

Snap-on DIN rail mount, 36 mm width (2 MW). Screw terminals accept 0.75–25 mm² solid or stranded conductors; torque to 2.5–3 N·m. Sealable (padlockable) for lockout/tagout. IP20 with conductors connected — suitable for enclosed distribution boards. Halogen-free and silicon-free construction for environments sensitive to outgassing.

Frequently asked questions

Where can I buy the 5SL4510-7CC and get a price?

The 5SL4510-7CC is sourced to order against an RFQ through independent distribution. Submit a request for current availability and pricing.

Will the 5SL4510-7CC drop into a panel specified for the 5SL4120-7CC?

Yes. Both are 1P+N, C-curve, 2-MW (36 mm) SENTRON MCBs with the same physical footprint and terminal specs. The only difference is the rated current — 10 A on the 5SL4510-7CC vs 20 A on the 5SL4120-7CC. No rewiring needed at the same current level.

What is the depth of the 5SL4510-7CC?

The depth is 76 mm, with an installation depth of 70 mm.

What conductor sizes does the 5SL4510-7CC accept?

Screw terminals accept solid or stranded conductors from 0.75 mm² up to 25 mm².

MPN
5SL4510-7CC