Siemens 5SL4514-8 SENTRON MCB, 2-pole 0.3 A D-curve, 10 kA

MPN5SL4514-8
Active

Siemens SENTRON 5SL miniature circuit breaker, 5SL4514-8, 2-pole 1P+N, 0.3 A rated current, D tripping characteristic, 10 kA breaking capacity, 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4514-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL4514-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Overvoltage category3
5SL4514-8 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL4514-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4514-8 is a SENTRON miniature circuit breaker in the 5SL4 design, rated 0.3 A at 230 V AC with a D tripping characteristic and a 10 kA breaking capacity per EN 60898 and IEC 60947-2. It's a 1P+N (2-pole) unit that switches the neutral conductor — a detail that matters when you need full isolation on a single-phase residential or light-commercial feeder. At 0.3 A it's a low-current branch protector, not a main feeder breaker. The 10 kA SCCR covers most domestic and light-industrial fault levels; the 230 V AC rating suits standard single-phase networks.

Panel fit and wiring constraints

The 5SL4514-8 occupies 2 width units (36 mm) on a DIN rail, with an installation depth of 70 mm and overall depth of 76 mm — standard for the 5SL family. Terminals accept solid or stranded copper from 0.75 to 25 mm²; tightening torque is 2.5 to 3 N·m. The sealable feature (padlockable toggle) allows lockout/tagout on the branch circuit without additional hardware.

Frequently asked questions

What is the breaking capacity of 5SL4514-8?

10 kA rated value per both EN 60898 and IEC 60947-2, at 230 V AC.

What does the D tripping characteristic mean for this 0.3 A MCB?

The D-curve allows magnetic trip at 10–20 times rated current (3–6 A), so it handles high inrush from small transformers, solenoid coils, or motor starters without nuisance tripping on startup.

Will 5SL4514-8 drop into a panel that was specified around 5SL6563-7BB without rewiring?

No — the 5SL6563-7BB is a different pole configuration and rating. The 5SL4514-8 is 1P+N at 0.3 A D-curve; the 5SL6563-7BB is a 3-pole unit at a higher current. They share the 5SL DIN-rail footprint and terminal range, but the circuit design and load protection differ. Verify the BOM line before substituting.

How do I get current pricing and availability for 5SL4514-8?

Submit an RFQ through the storefront. Pricing and stock are confirmed at quote time — we source through independent distribution channels and quote to order.