Siemens 5SL4550-8 — 1-Pole MCB (DIN Rail)

Siemens 5SL4550-8 SENTRON MCB, D Curve, 50 A, 2-Pole

MPN5SL4550-8
Active

Siemens SENTRON 5SL miniature circuit breaker, 5SL4550-8, D tripping characteristic, 50 A rated at 30 °C, 2-pole (1P+N), 10 kA breaking capacity per EN 60898 and IEC 60947-2, 230 V AC, 2 modular width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL4550-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL4550-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)10 kA
Energy limitation class3
Overvoltage categoryIII
5SL4550-8 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL4550-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL4550-8 is a SENTRON miniature circuit breaker (MCB) with a D tripping characteristic, rated 50 A at 30 °C and 230 V AC. It is a 2-pole unit (1P+N) that occupies 2 modular width units on a DIN rail, making it a direct drop-in for standard residential and infrastructure panels. The D curve means it tolerates high inrush currents — typical for motor, transformer, or lighting ballast loads — without nuisance tripping, while still providing short-circuit protection at 10 kA per EN 60898 and IEC 60947-2.

Ratings that matter for the BOM line

At 40 °C it derates to 46.19 A, at 45 °C to 44 A, and at 55 °C to 39.81 A — so if your panel runs warm, size the load accordingly. The 10 kA breaking capacity at 230 V AC covers most residential and light commercial fault levels; the same 10 kA applies under IEC 60947-2 for industrial installations. The part switches the neutral conductor (1P+N) and includes touch protection on the terminals.

Depth is 76 mm (installation depth 70 mm), width 36 mm (2 MW), height 90 mm. Sealable, halogen-free, silicon-free.

Frequently asked questions

How do I get current pricing and availability for 5SL4550-8?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock levels are confirmed at quote time.

What is the breaking capacity of 5SL4550-8?

10 kA per EN 60898 and 10 kA per IEC 60947-2 at 230 V AC.

What does the D tripping characteristic mean for this MCB?

The D curve trips magnetically at 10 to 20 times the rated current (500–1000 A for this 50 A unit), which suits loads with high inrush like motors, transformers, or discharge lighting. It avoids nuisance trips that a B or C curve would cause on those loads.

Will 5SL4550-8 drop into a panel specified around 5SL6550-7BB?

Both are 2-module-width SENTRON MCBs on the same DIN-rail footprint, so mechanical fit is the same. The key difference is the tripping characteristic: 5SL4550-8 is a D curve; 5SL6550-7BB is a different characteristic. Verify the curve matches your load before swapping.

MPN
5SL4550-8